Classic 10
Accessories
CONDENSER AIR REMOVAL
CONDENSER AIR REMOVAL
To exhaust the warm condenser air above the work area,
To exhaust the warm condenser air above the work area,
attach the warm air fl ange and duct to the top of the unit.
attach the warm air fl ange and duct to the top of the unit.
When inside an offi ce, simply replace the ceiling tile with
When inside an offi ce, simply replace the ceiling tile with
the unit ceiling tile and exhaust the warm air. No special
the unit ceiling tile and exhaust the warm air. No special
tools or equipment are required for the installation.
tools or equipment are required for the installation.
Warm Air Flange Kit
C10-5
12” diameter gray metal fl ange with wire clamp and
mounting screws.
Warm Air Duct
C10-6
12” adjustable diameter white plastic duct extends 7’ in length.
Ceiling Tile
C10-7
24” x 24” white tile with 12” hole for warm air duct.
AUTO CONDENSATE REMOVAL
AUTO CONDENSATE REMOVAL
Why bother with emptying the drain tank when you can install
Why bother with emptying the drain tank when you can install
a condensate pump to remove the water automatically!
a condensate pump to remove the water automatically!
This pump has an 18-foot lift capacity to reach virtually any
This pump has an 18-foot lift capacity to reach virtually any
remote drain.
remote drain.
PART NAME
CLASSIC 10
Cover Plate
C10-9
Blue metal plate covers condensate collection area.
Condensate Pump Kit
C10-10
110V pump kit includes 3/8” diameter x 20’ length
of hose and installation hardware.
MAKE-UP AIR
When balanced air fl ow is required, attach the air plenum
with a duct from the side of the unit to an outside air source.
with a duct from the side of the unit to an outside air source.
The air to the condenser is pulled from outside the room
The air to the condenser is pulled from outside the room
to eliminate problems associated with negative air pressure.
to eliminate problems associated with negative air pressure.
SPOT or REMOTE COOLING
SPOT or REMOTE COOLING
The amount of air supplied to remote areas can be quickly
The amount of air supplied to remote areas can be quickly
and conveniently increased by attaching 10’ extension ducts
and conveniently increased by attaching 10’ extension ducts
directly over the standard ducts. For more permanent
directly over the standard ducts. For more permanent
installations, use the fl ange and clamp to secure the
extension ducts to the unit.
extension ducts to the unit.
Cold Air Flange Kit
C10-1
5” diameter gray metal fl ange with wire clamp
and mounting screws.
Extension Duct
C10-2
5” diameter white plastic duct that extends from
6.5’ to 10’ in length.
Trim RIng
C10-3
5” diameter black plastic ring mounts as end caps
for extension ducts.
Dual Duct
C10-4
5” diameter white plastic fl ange with two 4” nozzles that
extend to 3.5’ in length.
Air Duct
C10-6
12” adjustable diameter white plastic duct extends 7’ in length.
Ceiling Tile
C10-7
24” x 24” white tile with 12” hole for warm air duct.
Air Plenum
C10-8
Blue metal plenum. (not shown)