Zephyr CPAE マニュアル

ページ / 27
12
Inst
allation - Internal Blower
Note: for External blower installation disregard the
instruction in this page and step ahead on page 14.
TOP DISCHARGE
(Vertical discharge)
The hood is ready to be used for vertical discharge,
proceed to install the internal blower (See next page).
REAR DISCHARGE
(Horizontal discharge)
Remove the internal blower support (Top side)
unscrewing the 4 fixing screws.
From the inside of the hood, rear side remove
cover/rectangular transition support from the range
hood body unscrewing the 4 fixing screws.
Install the motor support to the body of the hood
(Rear side) with 4 screws in place of the rear cover
previously removed.
Note! Lip of motor support must be towards the
inside of the hood in order for screw holes to line
up.
Close, from the inside of the hood, the top hole with
the cover/rectangular transition support and fix it to
the body of the hood with 4 screws (Screws holes
disposition is obliged!).