Smeg C36GGNU インストール手順

ページ / 24
Instructions for the installer
11
4.1
Instructions for wall mounting (primary system)
The anti-tip brackets are to be attached to the rear wall as shown. The
height of bracket location from the floor is determined after the range legs
have been adjusted to the installation height as shown in the installation
instructions and the range has been leveled.
1 Level the range using the adjustable leveling legs.
2 From the floor, measure the height of the notch found on the bracket. This notch corresponds to the
centerline of the holes for the screws that will fasten the brackets to the wall.
C24GGXU (
23 
15
/
16
 ”
 - 
608 mm)
C36GGXU (
35 
3
/
4
 ”
 - 
908 mm)
3 Attach the two anti-tip brackets to the wall using an appropriate fastener (for example, screws
appropriate for the type of wall). Respect the heights indicated in the figures using the appliance’s
dimensions as a guide. (Type of screw recommended 
1
/
4
”).
C24GGXU (
23 
15
/
16
 ”
 - 
608 mm)
C36GGXU (
35 
3
/
4
 ”
 - 
908 mm)