General notes
Fan operation
Note: Ventilation may not exit through an already 
operational smoke or exhaust chimney, nor a duct 
used for ventilating furnace installation areas.
If the ventilation is intended to pass through a 
smoke or exhaust that is not in operation, the 
responsible area heating inspector must give 
approval.
If the ventilation passes through an external wall, 
use a telescope wall sleeve.
Ventilation line
Note: The manufacturer does not assume any 
warranty for complaints attributable to the pipe 
section.
The device achieves its optimum performance by 
means of a short, straight exhaust air pipe and as 
large a pipe diameter as possible.
The optimum extraction performance is not 
achieved and fan noise is increased if exhaust air 
pipes are long and rough and if there is a large 
number of pipe bends or diameters less than 5 
15
/
16
” (150 mm).
The pipes or hoses for laying the exhaust air line 
must consist of non-combustible material.
Round pipes
An inner diameter of 5 
15
/
16
” (150 mm), but at least 4 
3
/
4
” (120 mm), is recommended.
Flat ducts
The inner cross-section must correspond to the 
diameter of the round pipes.
Ø 5 
15
/
16
” (150 mm) approx. 27 ½ sq in (177 cm
2
)
Ø 4 
3
/
4
” (120 mm) approx. 17 ½ sq in (113 cm
2
)
Flat ducts should have no sharp deflections.
Use sealing strip for deviating pipe diameters.
Electrical connection
9
WARNING
Risk of electric shock
Parts inside the appliance can have sharp 
edges. The connection cable can be damaged. 
Do not bend or pinch connection cables during 
installation.
Check your domestic installation before installing the 
appliance. Pay attention to suitable fusing of your 
domestic installation. The voltage and frequency of 
the appliance must agree with the electrical 
installation (see rating plate).
The appliance complies with protective class I and 
may only be operated with a PE conductor connection.
The installation must contain a disconnector with a 
contact opening of at least 
X
” (3 mm) that isolates all 
poles from the mains. It must still be accessible after 
installation.
Only an electrical specialist may lay or replace the 
connecting lead, paying attention to the applicable 
regulations.
If the mains connecting lead of this appliance is 
damaged, it must be replaced with a special 
connecting lead, which is obtainable from the 
manufacturer or the manufacturer's after-sales 
service.