Gaggenau AL400721 パンフレット
Ventilation appliances
207
V L 041 114
Stainless steel control panel
Control unit
Air extraction/recirculation with remote
fan unit AR 400/401/403/413
Control unit
Air extraction/recirculation with remote
fan unit AR 400/401/403/413
V L 040 114
Stainless steel control panel
Expansion elementx
Air extraction/recirculation with remote
fan unit AR 400/401/413
Expansion elementx
Air extraction/recirculation with remote
fan unit AR 400/401/413
V L 041 134
Aluminium control panel
Control unit
Air extraction/recirculation with remote
fan unit AR 400/401/403/413
Control unit
Air extraction/recirculation with remote
fan unit AR 400/401/403/413
V L 040 134
Aluminium control panel
Expansion elementx
Air extraction/recirculation with remote
fan unit AR 400/401/413
Expansion elementx
Air extraction/recirculation with remote
fan unit AR 400/401/413
Necessary installation accessories
A D 724 040
A D 724 040
Connection piece for cylindrical duct
DN 125
DN 125
A D 824 042
Flat duct system with conducting fins
Connection piece VL 041/040 for
DN 125 flat rectangular
Connection piece VL 041/040 for
DN 125 flat rectangular
A D 854 042
Flat duct system with conducting fins
Connection piece VL 041/040 for
DN 150 flat rectangular
Connection piece VL 041/040 for
DN 150 flat rectangular
Installation accessories
A S 070 000
A S 070 000
Connection piece for extension in the
case of installation next to VK or VF
case of installation next to VK or VF
L S 041 000
Air baffle for VL 040/041 next to gas
appliance
appliance
V V 200 014
Stainless steel connection strip for
combination with further Vario
cooktops
combination with further Vario
cooktops
V V 200 034
Aluminium connection strip for
combination with further Vario
cooktops
combination with further Vario
cooktops
Installation accessories for the air
recirculation ducts you will find at the
pages 236–239 .
recirculation ducts you will find at the
pages 236–239 .
Vario downdraft ventilation 200 series
V L 040/V L 041
– Ventilation element integrated in the
worktop
– Highly efficient ventilation system at
the cooktop
– Compact ducting in connection
with flat rectangular pipes AD 8..
– Minimal planning and easy
installation for air recirculation
Output
Maximum air output in combination
with remote fan units s. table remote
fan units on page 252/253.
Sound power level depends on the
built-in situation.
with remote fan units s. table remote
fan units on page 252/253.
Sound power level depends on the
built-in situation.
Features
Output control, knob operation.
4 output levels.
Ventilation grille can be washed.
Metal grease filter with grease
collecting insert.
No duct connection piece included.
4 output levels.
Ventilation grille can be washed.
Metal grease filter with grease
collecting insert.
No duct connection piece included.
Planning notes
No additional switch necessary.
Air extraction operation in combination
with remote fan units AR 400/401/403
or recirculation mode with AR 413.
Please refer to page 228–233 for
recommended configurations of
downdraft ventilations and remote fan
units and the needed ducting
elements.
Maximum cooktop width between two
VL: 60 cm (exception: VI/VE 270).
If installed next to gas appliances, the
air baffle LS 041 000 is recommended
to ensure maximum performance of the
cooktop. If installed next to gas
appliances, flat ducts must not be used
for the piping up to the fan unit.
When having installed the air baffle
LS 041 000 the wok pan WP 400 001
can not be used.
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood’s power sup-
ply line needs a suitable safety switch.
Do not fit in drawer area.
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
Duct connection downwards or
sidewards:
DN 125 cylindrical with connection
piece AD 724 040.
Optional DN 125/150 flat rectangular
duct with connection piece
AD 824/854 042 (installation
accessory).
Connection of 2 VL with ducting
2x DN 125 cylindrical or 2x DN 125/150
rectangular at remote fan AR 4.. .
For leading through the floor DN 150
cylindrical with connection of 2 DN 125
cylindrical use Y-joint AD 754 044.
Please ensure when installing the
exhaust air ducting that no sharp
bends are caused and that the
cross-section of the ducting is not
constricted in any way.
For downdraft configurations with
maximum lengths of exhaust air ducts
go to Rodun at www.gaggenau.com.
Appliance weight: approx. 4 kg.
Air extraction operation in combination
with remote fan units AR 400/401/403
or recirculation mode with AR 413.
Please refer to page 228–233 for
recommended configurations of
downdraft ventilations and remote fan
units and the needed ducting
elements.
Maximum cooktop width between two
VL: 60 cm (exception: VI/VE 270).
If installed next to gas appliances, the
air baffle LS 041 000 is recommended
to ensure maximum performance of the
cooktop. If installed next to gas
appliances, flat ducts must not be used
for the piping up to the fan unit.
When having installed the air baffle
LS 041 000 the wok pan WP 400 001
can not be used.
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood’s power sup-
ply line needs a suitable safety switch.
Do not fit in drawer area.
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
Duct connection downwards or
sidewards:
DN 125 cylindrical with connection
piece AD 724 040.
Optional DN 125/150 flat rectangular
duct with connection piece
AD 824/854 042 (installation
accessory).
Connection of 2 VL with ducting
2x DN 125 cylindrical or 2x DN 125/150
rectangular at remote fan AR 4.. .
For leading through the floor DN 150
cylindrical with connection of 2 DN 125
cylindrical use Y-joint AD 754 044.
Please ensure when installing the
exhaust air ducting that no sharp
bends are caused and that the
cross-section of the ducting is not
constricted in any way.
For downdraft configurations with
maximum lengths of exhaust air ducts
go to Rodun at www.gaggenau.com.
Appliance weight: approx. 4 kg.
Connection
Connecting cable 1.5 m with plug.