3.5 Air Flow
• Air drawn from the right side face passes through the condenser which extracts the heat. This
hot air is blown out through the upper exhaust air grill. Air taken in from the front face is cooled
by the evaporator and then blown through the cool air ducts. All the air inlets are equipped with
filters, and the exhaust air duct is protected by metal grill.
3.6 Compressor and Fans
• The compressor is hermetically sealed. A two-speed fan motor with two centrifugal fans are
used to draw air across the evaporator and condenser.
3.7 Drain Tank
• A 5.0 gal (19 L) drain tank is supplied with the Classic Plus 14. The condensate (water) is
collected into the tank.
The drain switch activates and stops the operation when tank reaches the level of approximately
4.0 gal (15 L).
I002314
Exhaust Air Out
Cool Air Out
Evaporator
Air In
Condenser Air In