TROUBLESHOOTING
Check the following items before calling your MovinCool reseller or a qualified 
technician.
If conditions persist after the above actions have been taken, turn the unit off, 
disconnect the power and contact your MovinCool reseller or a qualified 
technician. 
CONDITION
POSSIBLE CAUSE
REMEDY
Unit does not operate.
1. Ground fault breaker trip 
or LCDI power cord trip.
Reset breaker or reset power 
cord.
2. Drain tank is full.
(“TANK FULL” LED 
flashes.)
Empty the drain tank.
3. High pressure switch 
activated 10 times in 24 
hours.
1. Clean air filter.
2. Check inlet and outlet air 
to make sure that there 
are no objects preventing 
the air flow into or out from 
the unit.
3. Check environmental 
condition whether it is 
within operation range or 
not.
4. Reset controller.
To RESET: Press FAN HI/
LO and COOL ON/OFF 
buttons simultaneously for 
5 seconds, controller 
returns to normal 
operation.
Insufficient cooling.
1. Dirty/Blocked air filters.
Clean air filter.
2. Air inlet/outlet blocked.
Clean air inlet/outlet.
3. Improper temperature 
setting.
Adjust temperature setting.