Liebherr CS1350B インストール手順
1.2 Overview of the appliance and
accessories
Fig. 1
(1) Rear transport
handles
(9) Door racks
(2) Operating and control
elements
(10)Bottle shelf
(3) LED interior light
(11)Bottle rack
(4) Fan
(12)IceMaker
(5) Installation area,
adjustable
(13)Freezer compartment
(6) Drain hole
(14)VarioSpace
(7) Coldest zone
(15)Rating plate
(8) Vegetable drawer
(16)Adjustable feet, front
transport handles, rear
transport castors
1.3 Range of appliance use
Normal use
The appliance is only suitable for cooling food for
The appliance is only suitable for cooling food for
residential or other similar environments. This
includes the following types of uses
-
in staff kitchens, bed and breakfast establish-
ments,
-
by guests in country homes, hotels, motels
and other types of accommodations,
-
for catering and similar wholesale services.
All other types of uses are not permitted.
Foreseeable misuse
The following uses are specifically prohibited:
Foreseeable misuse
The following uses are specifically prohibited:
-
Storage and cooling of medication, blood
plasma, laboratory preparations or similar
substances and products in accordance with
the CMDCAS and FDA 510(k)
-
Use in areas at risk of explosion
Incorrect appliance use can cause damage to
the stored products or cause them to spoil.
Climate ratings
The appliance is set to operate within specific
Climate ratings
The appliance is set to operate within specific
ambient temperature limits according to its
climate rating. The climate rating for your appli-
ance is printed on the rating plate.
Note
Note
u
To guarantee trouble-free operation, comply
with the indicated ambient temperatures.
Climate
rating
for ambient temperatures from
SN
50 °F (10 °C) to 90 °F (32 °C)
N
61 °F (16 °C) to 90 °F (32 °C)
ST
61 °F (16 °C) to 101 °F (38 °C)
T
61 °F (16 °C) to 110 °F (43 °C)
1.4 Conformity
The refrigerant circuit has been tested for leaks. The
appliance complies with the relevant safety regulations
and the directives UL250 and CAN/CSA C22.2 No.63-93.
Instructions for testing institutes:
Instructions for testing institutes:
Tests must be carried out in accordance with the appli-
cable standards and guidelines.
The preparation and testing of the appliance must be
carried out taking account of the manufacturer's
loading plans and the instructions in the operating
manual .
The appliance at a glance
* Depending on model and options
3