SPECIFICATIONS
Gas Supply
Installation must conform with local codes or, in the absence 
of local codes, with the National Fuel Gas Code.
Locate the gas supply within the shaded area shown in the 
illustration on page 6.
The range is equipped for use with natural or liquid propane 
(LP) gas. It is design certified by the Canadian Standards 
Association (CSA) for natural or LP gases. The product 
rating plate has information on the type of gas that should 
be used. For rating plate location, refer to the illustration on 
page 3. If this information does not agree with the type of 
gas available, check with the local gas supplier.
GAS SUPPLY REQUIREMENTS
NATURAL GAS
Gas Supply Pressure
5"
 (12.5 mb)
 WC
Min Line Pressure
7"
 (17.5 mb)
 WC
Max Pressure to Regulator
14"
 (34.9 mb)
 WC, .5 psi 
(3.5 kPa)
LP GAS
Gas Supply Pressure
10"
 (25 mb)
 WC
Min Line Pressure
11"
 (27.4 mb)
 WC
Max Pressure to Regulator
14"
 (34.9 mb)
 WC, .5 psi
 (3.5 kPa)
The range must be connected to a regulated gas supply. 
The supply line must be equipped with an approved external 
gas shut-off valve located near the range in an accessible 
location. Do not block access to the shut-off valve. Refer to 
the illustration below.
A gas supply line of 
3
/
4
"
 (19)
 rigid pipe must be provided to 
the range. If local codes permit, a certified, 3'
 (.9 m)
 long, 
1
/
2
"
 (13)
 or 
3
/
4
"
 (19)
 ID flexible metal appliance connector is 
recommended to connect the units 
1
/
2
" NPT female inlet to 
the gas supply line. Pipe joint compounds, suitable for use 
with natural or LP gas should be used.
Wolf natural and LP gas ranges will function up to 10,250'
 
(3124 m)
 in altitude without adjustment. If the installation 
exceeds this elevation, contact an authorized Wolf dealer for 
a high altitude conversion kit.
SHUT-OFF VALVE
OPEN POSITION
GAS SUPPLY
TO APPLIANCE
 
Gas shut-off valve.