Zephyr AK2136BW オーナーマニュアル

ページ / 72
8
www.zephyronline.com
Installation – 
Mounting Height & Clearance
DUCTING
A minimum of 6” round for AK65 and 7” round 
for AK21 and AK25 or 3-1/4” x 10” rectangular 
GXFWPXVWEHXVHGWRPDLQWDLQPD[LPXPDLUÀRZ
HI¿FLHQF\
Always use rigid type metal ducts only. Flexible 
GXFWVFRXOGUHVWULFWDLUÀRZE\XSWR
$OVRXVHFDOFXODWLRQ RQSDJH WRFRPSXWHWRWDO
available duct run when using elbows, transitions 
and caps.
ALWAYS, when possible, reduce the number or 
transitions and turns. If long duct run is required, 
increase duct size from 6” to 7” or 7” to 8”. 
If turns or transitions are required; install as far 
away from hood duct output and as far apart, 
between the two as possible.
Minimum mounting height between range top to 
hood bottom should be no less than 24”. 
Maximum mounting height should be no higher 
than 32”.
It is important to install the hood at the proper 
mounting height. Hoods mounted too low could 
UHVXOWLQKHDWGDPDJHDQG¿UHKD]DUGZKLOH
hoods mounted too high will be hard to reach and 
ZLOOORVHLWVSHUIRUPDQFHDQGHI¿FLHQF\
If available, also refer range manufacturer’s height 
clearance requirements and recommended hood 
mounting height above range.
Vertical Ducting: 
´URXQGPLQLPXP $.
´URXQGPLQLPXP $.$.
3-1/4” x 10” rectangular minimum
Horizontal Ducting:
3-1/4”x10” rectangular minimum
DAMAGE-SHIPMENT / INSTALLATION:
‡ 3OHDVHIXOO\LQVSHFWXQLWIRUGDPDJHEHIRUH
installation.
‡ ,IWKHXQLWLVGDPDJHGLQVKLSPHQWUHWXUQWKH
unit to the store in which it was bought for 
repair or replacement.
‡ ,IWKHXQLWLVGDPDJHGE\WKHFXVWRPHUUHSDLU
or replacement is the responsibility of the 
customer.
‡ ,IWKHXQLWLVGDPDJHGE\WKHLQVWDOOHU LIRWKHU
WKDQWKHFXVWRPHU UHSDLURIUHSODFHPHQW
must be made by arrangement between 
customer and installer.
36”
24” min.
32” max.