Frigidaire FHWC3640MS オーナーマニュアル

ページ / 17
9
To wire through top:
Mark a line distance (A) from the right of the    
  centerline on the underside of the cabinet. Mark the 
  point on this line that is 
7
8
” (2.2 cm) from back wall. 
  Drill a 1¼” (3.2 cm) diameter hole (B) through the  
  cabinet at this point. 
 
 
 
 
To wire through wall:
Mark a line distance (A) from the right of the  
  centerline on the underside of the wall. Mark the point  
  on this line that is 
7
8
” (2.2 cm) from the underside of   
  the cabinet. Drill a 1¼” (3.2 cm) diameter hole (B) 
  through the rear wall at this point. 
 
 
 
 
 
 
 
 
 
 
 
 
VENTING 
Choose venting exhaust discharge from the various  
options listed - Style 1 - 4 that follows: 
 
Style 1 - Recirculating Hood version 
For this installation, go to “Install Range Hood  
(recirculating version)” on page 13.
.
1.
A
Centerline
7
8
” (2.2 cm)
from wall,
not cabinet frame
B
hood 
model
Dim 
A
30” & 36” 
models
8³⁄
8
” 
(21.3 cm)
A
A Centerline
7
8
” 
(2.2 cm)
hood 
model
Dim 
A
30” & 36” 
models
8³⁄
8
” 
(21.3 cm)
B
Style 2 - Cut Openings for 3¼” x 10” (8.3 cm x 
.4 cm) Rectangular Vent System
Roof Venting
To make a 4” x 10½” (10.16 cm x 26.7 cm) rectangular 
cutout on the underside of cabinet top and bottom:
Mark lines ½” (1.3 cm) and 4¾” (12.1 cm) from the    
  back wall on the centerline of the underside of cabinet.
Mark lines 5¼” (13.3 cm) to the right and left of the    
  centerline on the underside of cabinet.
Use saber or keyhole saw to cut a rectangular opening  
  for vent.
Repeat steps 1-3 for the underside of the top of the    
  cabinet.
 
 
Wall Venting
To make a 3½” x 10½” (8.9 cm x 26.7 cm) rectangle in 
the wall:
Make 2 lines by measuring ⅜” (0.9 cm) and 3⅞” 
  (9.8 cm) down from underside of cabinet and mark on 
  the centerline on the back wall.
Mark lines 5¼” (13.3 cm) to the right and left of the 
  centerline on the wall.
Use saber or keyhole saw to cut a rectangular opening 
  in the wall for the vent.
 
 
 
 
1.
.
.
4.
1.
.
.
Cabinet cutouts
*From wall, not cabinet frame
*
1
/
2
 (1.3 cm)
5
1
/
4
 
(13.3 cm)
5
1
/
4
 
(13.3 cm)
*4
3
/
4
 
(12.1 cm)
Cabinet  
front
Centerline
5
1
/
4
(13.3 cm)
3
7
8
” 
(9.8 cm)
3
8
 
(0.9 cm)
5
1
/
4
(13.3 cm)
Centerline
PREPARE THE LOCATION