KitchenAid KOSE500EBS 寸法図

ページ / 2
27" (68.6 CM) AND 30" (76.2 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
KODE300E
KODE307E
KODE500E
KODE507E
KODT100E 
KODT107E
KOSE500E
KOSE507E
KOST100E
KOST107E
KEBS109E
KEBS209E
Electrical: To properly install your oven, you must determine the type 
of electrical connection you will be using and follow the instructions 
provided for it here.
•  Oven must be connected to the proper electrical voltage and 
frequency as specified on the model/serial number rating plate. The 
model/serial number rating plate is located under the control panel on 
single ovens and under the control panel on the upper oven cavity on 
double ovens. See the following illustrations.
•  Models rated from 7.3 to 9.6 kW at 240 volts (5.4 to 7.4 kW at 208 
volts) require a separate 40-amp circuit. Models rated at 4.8 kW and 
below at 240 volts (3.6 kW and below at 208 volts) require a separate 
20-amp circuit.
• A circuit breaker is recommended.
•  Connect directly to the circuit breaker box (or fused disconnect) 
through flexible, armored or nonmetallic sheathed, copper cable (with 
grounding wire). See “Make Electrical Connection” section.
•  Flexible conduit from the oven should be connected directly to the 
junction box.
• Fuse both sides of the line.
•  Do not cut the conduit. The length of conduit provided is for 
serviceability of the oven.
•  A UL listed or CSA approved conduit connector must be provided.
•  If the house has aluminum wiring, follow the procedure below: 
1.   Connect a section of solid copper wire to the ends of the flexible 
conduit leads.
   2.   Connect the aluminum wiring to the added section of copper wire 
using special connectors and/or tools designed and UL listed for 
joining copper to aluminum.
Follow the electrical connector manufacturer's recommended 
procedure. Aluminum/copper connection must conform with local 
codes and industry accepted wiring practices.
For power requirements for models KOST107E, KOST100E, 
KOSE507E, KOSE500E, KODE307E, KODE300E, KODE507E, 
KODE500E, KODT100E and KODT107E, refer to the following table.
B
D
E
A
C
G
F
27" (68.6 cm) models
A.  28¾" (72.8 cm) max. overall 
height
B.   25
7
16
" (64.6 cm) max. recessed 
width
C.   26³⁄
4
" (67.9 cm) recessed 
height
D.   23¹⁄
4
" (59.1 cm) max. recessed 
depth
E.  27" (68.6 cm) overall width
F.  12" (30.5 cm) from back of 
control panel to start of strain 
relief
G.  48" (121.9 cm) flexible conduit 
length
Because Whirlpool Corporation includes a continues commitment to improve 
our products, we reserve the right to change materials and specifications 
without notice.
Dimensions are for planning purposes only. For complete details, 
see Installation Instructions packed with product. Specifications 
subject to change without notice.
Ref. W10725670B
03/15
A
A
S ingle  Oven 
A.  Model/serial number plate
D ouble  Oven 
A.  Model/serial number plate
Voltage
Single 
Thermal
Single 
Convect
Double 
Thermal
Double 
Convect
Double 
Convect/ 
Thermal
240 VAC
4100 W
4100 W
8163 W
8300 W
8300 W
208 VAC
3100 W
3100 W
6300 W
6300 W
6300 W
240 VAC
17.2 A
17.2 A
34.2 A
34.2 A
34.2 A
208 VAC
15.0 A
15.0 A
29.9 A
29.9 A
29.9 A
30" (76.2 cm) models
A.  28¾" (72.8 cm) max. overall 
height
B.  28½" (72.4 cm) max. recessed 
width
C.   26³⁄
4
" (67.9 cm) recessed height
D.   23¹⁄
4
" (59.1 cm) max. recessed 
depth
E.  30" (76.2 cm) overall width
F.  12" (30.5 cm) from back of 
control panel to start of strain 
relief
G.  48" (121.9 cm) flexible conduit 
length
C
B
A
E
D
G
F
27" (68.6 cm) models
A.   51³⁄
16
" (130.0 cm) 
max. overall height
B.   25
7
16
" (64.6 cm) 
max. recessed width
C.   48¹³⁄
16
" (124.0 cm) 
recessed height
D.   23¹⁄
4
" (59.1 cm) 
max. recessed depth
E.  27" (68.6 cm) overall width
F.  12" (30.5 cm) from back 
of control panel to start 
of strain relief
G.  66" (167.6 cm) flexible 
conduit length
30" (76.2 cm) models
A.   51³⁄
16
" (130.0 cm) 
max. overall height
B.  28½" (72.4 cm) 
max. recessed width
C.   48¹³⁄
16
" (124.0 cm) 
recessed height
D.   23¹⁄
4
" (59.1 cm) 
max. recessed depth
E.  30" (76.2 cm) overall width
F.  12" (30.5 cm) from back 
of control panel to start 
of strain relief
G.  66" (167.6 cm) flexible 
conduit length
Page 1 of 2