Electrical Requirements - Canada Only
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that the 
ground path is adequate and wire gauge are in accordance with 
local codes.
Be sure that the electrical connection and wire size are adequate 
and in conformance with CSA Standard C22.1, Canadian Electrical 
Code, Part 1 - latest edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
Check with a qualified electrical installer if you are not sure the 
range is properly grounded.
*The NEC calculated load is less than the total connected load 
listed on the model/serial/rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with 
kit. For 50-amp rated cord kits, use kits that specify use with a 
nominal 1
³⁄₈" (34.9 mm) diameter connection opening.
A time-delay fuse or circuit breaker is recommended.
This range is equipped with a CSA International Certified Power 
Cord intended to be plugged into a standard 14-50R wall 
receptacle. Be sure the wall receptacle is within reach of 
range’s final location.
Do not use an extension cord.
INSTALLATION INSTRUCTIONS
Unpack Range
1. Remove shipping materials, tape and film from the range. Keep 
cardboard bottom under range.
2. Remove oven racks and parts package from inside oven.
3. To place range on its back, take 4 cardboard corners from the 
carton. Stack one cardboard corner on top of another. Repeat 
with the other 2 corners. Place them lengthwise on the floor 
behind the range to support the range when it is laid on its 
back.
4. Using 2 or more people, firmly grasp the range and gently lay it 
on its back on the cardboard corners.
5. Pull cardboard bottom firmly to remove.
6. Use an adjustable wrench to loosen the leveling legs.
7. Place cardboard or hardboard in front of range. Using 2 or 
more people, stand range back up onto cardboard or 
hardboard.
Adjust Leveling Legs
1. If range height adjustment is necessary, use a wrench or pliers 
to loosen the 4 leveling legs.
This may be done with the range on its back or with the range 
supported on 2 legs after the range has been placed back to a 
standing position.
NOTE: To place range back up into a standing position, put a 
sheet of cardboard or hardboard in front of range. Using 2 or 
more people, stand range back up onto the cardboard or 
hardboard.
2. Adjust the leveling legs to the correct height. Leveling legs can 
be loosened to add up to a maximum of 1" (2.5 cm). A 
minimum of 
³⁄₁₆" (5.0 mm) is needed to engage the anti-tip 
bracket.
NOTE: If height adjustment is made when range is standing, tilt 
the range back to adjust the front legs, then tilt forward to 
adjust the rear legs.
3. When the range is at the correct height, check that there is 
adequate clearance under the range for the anti-tip bracket. 
Before sliding range into its final location, check that the anti-tip 
bracket will slide under the range and onto the rear leveling leg 
prior to anti-tip bracket installation.
WARNING
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or 
electrical shock.
Range Rating*
Specified Rating of 
Power Supply Cord Kit 
and Circuit Protection
120/240 Volts
120/208 Volts
Amps
8.8 - 16.5 KW
16.6 - 22.5 KW
7.8 - 12.5 KW
12.6 - 18.5 KW
40 or 50
50
WARNING
Excessive Weight Hazard
Use two or more people to move and install range.
Failure to do so can result in back or other injury.