WineMate Split System Wine Cooling Units - 2000 Cu. Ft. Wine Cellar インストールガイド

ページ / 3
                                                                                
- 1 -
VINO2500SSD, 4500SSD 
VINO6500SSD, 8500SSD 
Installation Instruction 
 
 
Federal law requires that WINEMATE split cooling systems be 
installed by an EPA certified refrigeration technician.
 
 
1. Location 
 
•  Place the condensing unit in a properly ventilated location. If it is not, heat 
exhausted by the condensing unit will build up and the cooling system will 
not operate properly.  
•  Leave minimum 3 feet clearance between the exhaust side and the wall. 
•  Leave minimum 1 foot clearance for the fresh air supply side. 
•  Condensing unit should be elevated to avoid possible flooding and shaded 
from direct sun. It should not be exposed to temperatures higher than 125 
°
F or lower than 20 
°
F.  
•  Air flow from the unit cooler should be unobstructed for at least 1 foot. 
 
2. Refrigeration Installation 
 
Model 
Liquid Line Diameter 
(inch), recommended 
 
Suction Line Diameter 
(inch), recommended 
 
VINO2500SSD 1/4 
3/8 
VINO4500SSD 1/4 
1/2 
VINO6500SSD 1/4 
5/8 
VINO8500SSD 3/8 
5/8 
 
WINEMATE split system is shipped as components and is ready for use only 
after a certified refrigeration technician has properly installed and tested the 
system. Proper installation is critical.  WINEMATE can only warrant the quality of