10
 
 
 
1) Display 
During normal working conditions, the display shows the value measured by the 
air regulation probe or the second probe (parameter /4). In case of active alarm, 
the temperature flashes alternately to the code alarm. 
  
2) Alarm Code Description 
E0: fault air regulation probe 
E1: evaporator product/food probe fault digital input alarm 
IA:  immediate external alarm (A4 and A7 parameters) 
LO: low temperature alarm (AL, Ad and A0 parameters) 
HI: high temperature alarm (AH, Ad and A0 parameters) 
EE: data acquisition failure (see the manual for the default procedure) 
Ed: timeout-ended defrost (dt, dP and r3 parameters) 
dF: defrost in progress 
 
3) Operating Indications on the Display 
LED 1 or LED Button 5 indicates compressor ON; 
LED 3 or LED Button 7 indicates defrosting ON; 
LED 2 or LED Button 6 indicates presence of alarms. 
* The blinking indicates that controller is waiting for a time delay to expire. 
 
4) Set-Point (desired temperature value) 
Press the SET button 6 for one second to display the Set-Point value; 
After few seconds, the set value blinks; 
Press UP button 5 or DOWN button 7 to increase or decrease the set-point 
value;  
Press the SET button 6 once more to confirm the new value. 
 
5) Manual Defrost 
Besides the automatic defrost, it is possible to activate a manual defrost by 
pressing the button 7 for more than 5 seconds (it occurs only in the appropriate 
temperature conditions).