WineMate Split System Wine Cooling Units - 1000 Cu. Ft. Wine Cellar 使用とお手入れ

ページ / 16
                                                                                
- 11 -
Troubleshooting 
 
This Troubleshooting Chart is not prepared to replace the training required for a 
professional refrigeration service person, not is it comprehensive 
 
Troubleshooting Chart 
Complaint Possible 
Causes 
Response 
1. Unit not running 
 
a.  Power cord unplugged 
b.  No power to unit 
c. Temperature 
setting 
high 
d. Low 
voltage. 
e.  Incorrect or loose wirings. 
f. Defrost 
light 
blinking 
g.  Running light blinking 
 
a.  Check for power cord plug 
b.  Check power at receptacle & fuses 
c. Lower 
temperature 
setting 
d.  Contact an authorized electrician  
e.  Check all wirings and connections 
f. Under 
defrost 
g.  Call service for failed components 
2. Compressor stopping and starting but short running time
 
 
a.  Incorrect temperature setting  
b. Incorrect 
voltage 
c. Failed 
thermistor 
 
d. Failed 
components 
 
e. Improper 
condenser 
airflow 
f. Dirty 
condenser 
g.  Overcharge of refrigerant 
h.  Discharge or suction pressure too 
high 
a.  Set 55 to 60 
°
F  
b.  Check for voltage 
c.  Check thermistor by placing it in ice 
water and measuring resistance 
d.  Check compressor windings, start 
relay and overload protector. 
e.  Check for condenser fan  
f. Clean 
condenser 
g.  Call service for removing refrigerant 
h.  Call service for OEM information 
 
3. Fan motor running but compressor not running 
 
a.  Incorrect power supply 
b.  Incorrect or loose wirings 
c. Failed 
components 
 
d.  Liquid refrigerant in the compressor 
a.  Check for proper voltage 
b.  Check all wirings and  connections 
c.  Check start relay, start capacitor, 
overload protector, compressor. 
d.  Call service for OEM information. 
4. Compressor running but fan not running 
 
a.  Fan blade bond 
b.  Incorrect or loose wirings 
c. Failed 
motors 
a.  Check for proper clearance 
b.  Check all wirings 
c.  Call service for checking open or 
shorted windings 
5. No cooling but compressor and fan running  
 
a.  Evaporator airflow restriction 
b. Refrigerant 
leakage 
c. Refrigeration 
system restriction 
a.  Check for airflow through evaporator 
b.  Check for loss of refrigerant 
c.  Call service for checking  restrictions
6. Temperature too high or unit running too long 
 
a.  Improper evaporator or condenser 
airflow 
b. Dirty 
Condenser 
c. Iced 
evaporator 
d. Malfunctioning 
fans 
e. Improper 
seals 
f. 
Improper area to be cooled. 
 
a.  Check for air restrictions 
 
b. Clean 
condenser 
c.  Defrost and reset temperature 
d.  Check for both fans  
e.  Check for gasket and door opening 
f.  Check for excessive load incorrect 
installation