•  Use dry nitrogen to purge the system. 
•  Do not overcharge the refrigeration system. 
•  Do not leave replacement compressor open to the atmosphere for more 
than 10 minutes. 
•  Do not operate the compressor without refrigerant charge in the system. 
•  Do not use the compressor if the rubber plugs on the replacement 
compressor appear to have been tampered or removed. 
•  Always replace the filter-drier when performing any repairs on the sealed 
system.  
•  The filter-drier must be cut from the sealed system. Never unbraze the 
filter-drier from system tubing. Applying heat will drive moisture back into 
sealed system. 
 
 
Table 1-1 Health and Safety Handling of R134a 
Allowable Overall Exposure Limit  1,000 ppm 
Vapor Exposure to Skin 
No Effect 
Liquid Exposure to Skin 
Can cause frostbite 
Vapor Exposure to Eyes 
Can cause very slight irritation 
Liquid Exposure to Eyes 
Can cause frostbite 
Above Minimum Exposure Limit 
Can cause asphyxiation, tachycardia 
and cardiac arrhythmia's. Wear 
appropriate skin and eye care. 
Spill Management 
Combustible sources. Evacuate or 
ventilate area. 
May decompose if in contact. 
Fire and Explosion Hazards 
Made with flames and heating 
elements. Container may explode if 
heated due to pressure rise. 
Combustion products are toxic. 
 
Storage Conditions 
The  procedures/rules for R12 also 
apply to R134a. 
Reclaim 
 
 
 
 
 
 
 
 
 
 
 
                                                                                               