Perlick 15" Signature Series Beer Dispenser - Fully Integrated Door - Right Hinge 取り扱いマニュアル

ページ / 22
BEER DISPENSERS
Operation / Installation Manual
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice 
9
BEER DISPENSERS
Operation / Installation Manual
CONNECTING THE REGULATOR TO THE 
CO
2
 CYLINDER
.
■ Remove.blue.plug.from.regulator.fitting..(Note:.
Do.not.remove.the.carbonic.washer),
.
■ Screw.regulator.onto.gas.cylinder.valve..
Tighten.with.wrench.until.vertically.straight..Be.
sure.that.shut-off.valve.on.regulator.is.in.the 
OFF.(horizontal).position.
.
■ Place.a.screw.clamp.over.end.of.red.line.and.
push.onto.regulator.tailpiece..Tighten.clamp.
with.a.screwdriver.
.
■ Turn.regulator.adjusting.screw.counterclockwise.
until.it.turns.freely.
.
■ Turn.hand.valve.counterclockwise.on.CO
2
.
cylinder.to.the.fully.open.position.
.
■ Turn.regulator.adjusting.screw.clockwise.until.
desired.pressure.is.reached.(approximately.
12-15.lbs.)..Tighten.stop.nut.on.adjusting.
screw.
.
■ Open.shut-off.valve.on.bottom.of.regulator.
CO
2
 LEAK TEST
Dilute.a.small.amount.of.liquid.dishwashing.
soap.and.rub.the.soapy.mixture.around.each.
connection..If.bubbles.appear,.tighten.connection.
REPLACING THE CO
2
 GAS CYLINDER
.
■ Turn.CO
2
..hand.valve.clockwise.until.seated.
and.close.shut-off.valve.on.regulator.
.
■ Unscrew.regulator.from.cylinder.fitting.
.
■ Replace.carbonic.washer.(Part.No..157F2P),.
if.needed,.and.reattach.regulator.to.filled.
cylinder.
.
■ Turn.CO
2
..hand.valve.counterclockwise.until.
fully.open..Turn.regulator.shut-off.valve.to.
open.position.
.
■ Adjust.CO
2
..gas.flow.as.required,.turning.
clockwise.for.higher.pressure..
FAILURE  TO  HEED  THE  WARNINGS  ON 
THIS PAGE COULD RESULT IN PERSONAL 
INJURY OR DEATH.
PROPER CO
2
 HANDLING
ALWAYS...
.
■ Connect. a. regulator. (reducing. valve). to. CO
2
.
cylinder.
.
■ Secure. cylinder. in. upright. position. whether. in.
storage.or.in.use.
.
■ Keep. cylinder. away. from. heat.. Rupture. disc.
vents.at.122°F.maximum.
.
■ Ventilate.room.after.gas.leakage.
.
■ Check.the.last.DOT.test.date.on.cylinder.neck.
before. filling.. If. more. than. five. years. old,. the.
cylinder.must.be.retested.to.DOT.specifications.
.
■ Be.sure.CO
2
.cylinder.outlet.fitting.is.free.of.dust.
or.dirt.before.attaching.regulator.
.
■ Store. CO
2
. cylinder. and. regulator. assembly.
upright.
.
■ Allow. only. properly. trained. and. experienced.
personnel.to.handle.high.pressure.gas.