Preparing for Installation
Plan the installation so that the electrical connection, gas shut-off valve, and
pressure regulator are accessible from the front of the cabinet and so that all of the
minimum required
dimensions are provided.
Dimensions apply to both
models unless otherwise
stated (see Figure 1). Locate
the electrical supply box
within reach of the included
48 inch long flexible cord so
the connection is accessible
when the cooktop is in place.
IMPOR
IMPOR
IMPOR
IMPOR
IMPORT
T
T
T
TANT
ANT
ANT
ANT
ANT
When  installing  the  cooktop  into  a  laminated  (Formica,  etc.)  or  synthetic  (Corian,
etc.)  countertop,  radius  the  corners  of  the  cutout  to  prevent  cracking  of  the
countertop.
Follow  the  countertop  manufacturer’s  instructions  regarding  the  minimum  corner
radius,  use  of  heat  reflective  tape,  reinforcement  of  corners,  etc.
If  cabinet  storage  space  is  to  be  provided  directly  above  the  cooktop,  the  risk  of
personal  injury  may  be  reduced  by  installing  a  ventilating  hood  that  projects
horizontally  a  minimum  of  5  inches  beyond  the  face  of  the  cabinets.
Both  models  are  designed  to  allow  installation  in  standard  24  inch  deep  base
cabinets  with  25  inch  overall  depth  countertops.  Deeper  cabinets  and
countertops  may  be  used  to  provide  required  clearances  to  combustible  rear  wall
materials  or  for  design  purposes.
The  specified  cabinet  dimensions  must  be  provided.  The  cabinet  and/or
countertop  must  completely  enclose  the  recessed  portion  of  the  countertop.
All  contact  surfaces  between  the  appliance  and  the  countertop  must  be  solid
and  level.
Hood
E36GC76EPS: 42" (1067mm) Recommended
36" (914mm) Minimum
E48GC76EPS: 54" (1372mm) Recommended
48" (1219mm) Minimum
Cooktop opening
E36GC76EPS: 36" (914mm)
E48GC76EPS: 48" (1219mm)
10" (254mm)
Min. to 
combustible side 
wall, both sides
5/8" (16mm) Overhang, both sides
1 1/2" (38mm)
Typical Countertop
18"
(457mm)
30" (762mm)
Minimum
36"
(914mm)
28 1/4"
(717mm)
7 3/4"
(197mm)
Utilities
Location
C
L
6"
(152mm)
E36GC76EPS: 
24" (610mm)
E48GC76EPS: 30" (762mm)
10"
(254mm)
15 1/2"
(393mm)
Figure  1
E36GC76EPS: 36” (914mm) Minimum
E48GC76EPS: 48” (1219mm) Minimum