Electrolux E15IM60GSS オーナーマニュアル

ページ / 22
5
Installation
Installation Dimensions
Installing the Drain
       CAUTION
PLEASE READ all instructions completely 
before attempting to install or operate the unit. 
All ice makers require a connection to the 
water supply and improper hook-up can result 
in substantial property damage! All water 
and drain connections MUST BE made by a 
licensed/qualified plumbing contractor. Failure 
to follow recommendations and instructions 
may result in damage and/or harm.
       CAUTION
Plumbing installation must observe all 
state and local codes. All water and drain 
connections MUST BE made by a licensed/
qualified plumbing contractor. Failure to follow 
recommendations and instructions may result 
in damage and/or harm.
Model EI15IM55GS can be installed using a gravity 
drain or the Electrolux EIMP60, optional drain 
pump kit.
Follow these guidelines when installing drain lines 
to prevent water from flowing back into the ice 
maker storage bin and/or potentially flowing onto 
the floor causing water damage:
Gravity Drain
•     Drain lines must have a 5/8 inch inside 
diameter.
•     Drain lines must have a 1 inch drop per 48 
inches of run (1/4 inch per foot) and must not 
create traps.
•     The floor drain must be large enough to 
accommodate drainage from all drains.
•     Insulate the bin drain line to prevent 
condensation.
14 - 15/16”
(37.9)
24”
(61)
5”
(12.7)
21 - 3/4”
(55.2)
34 - 1/8”
(86.7)
FULL
RETRACT
HEIGHT
WATER
VALVE
WATER
OUTLET
WATER
DRAIN
Figure 1