Installation
Connecting a Drain Pump
If a gravity drain connection is not available, we 
strongly recommend the use of the Electrolux 
EIMP60 drain pump. The Electrolux EIMP60 
drain pump is available through your Dealer, or 
direct from Electrolux with complete installation 
instructions. If a pump other than the Electrolux 
EIMP60 drain pump is to be used, it must meet the 
following specifications:
•     It must be UL listed and have a UL listed, 
120 VAC, 3-wire grounded power cord.
•     It must have overall maximum outside 
dimensions of 8-3/4” wide x 5-3/4” deep x 
7-3/4” high.
•     It must have a minimum flow rate of 15 
gallons per hour at 10 feet of lift.
•     It must have a sealed sump which does not 
allow water leakage in the case of a power 
outage, restricted drain or pump failure.
•     It must have a check valve in the discharge 
line to prevent waste water return to the 
pump.
•     It must have an overflow protection control 
which will shut off power to the ice maker in 
the event of a pump failure.
•     It must have an operating temperature range 
of 50°F to 110°F (10°C to 43°C).
       CAUTION
In the event of a power outage, restricted drain 
or pump failure, the failure to use the 
Electrolux EIMP60 drain pump or a pump with 
the above listed specifications, could result 
in substantial water leakage and pooling with 
severe and costly water damage and related 
consequential damages and harm.