NOTICE - This service data sheet is intended for use by persons having electrical 
and mechanical training and a level of knowledge of these subjects generally 
considered acceptable in the appliance repair trade. The manufacturer cannot 
be responsible, nor assume any liability for injury or damage of any kind arising 
from the use of this data sheet.
SAFE SERVICING PRACTICES
To avoid the possibility of personal injury and/or property damage, it is important 
that safe servicing practices be observed. The following are examples, but without 
limitation, of such practices.
1.  Before servicing or moving an appliance remove power cord from electrical outlet, 
trip circuit breaker to OFF, or remove fuse.
2.  Never interfere with the proper installation of any safety device.
IMPORTANT
DO NOT REMOVE THIS BAG
OR DESTROY THE CONTENTS
WIRING DIAGRAMS AND SERVICE
INFORMATION  ENCLOSED
REPLACE CONTENTS IN BAG
p/n A00498601 Rev A (1408)
SERVICE DATA SHEET
30” INDUCTION COOKTOP
3.  GROUNDING: The standard color coding for safety ground wires is GREEN or 
GREEN WITH YELLOW STRIPES. Ground leads are not to be used as current 
carrying conductors. 
It is extremely important that the service technician 
reestablish all safety grounds prior to completion of service. Failure to do 
so will create a potential safety hazard.
4.  Prior to returning the product to service, ensure that:
 
• All electric connections are correct and secure.
 
• All electrical leads are properly dressed and secured away from sharp edges, 
high-temperature components, and moving parts.
 
• All uninsulated electrical terminals, connectors, heaters, etc. are adequately 
spaced away from all metal parts and panels.
 
• All safety grounds (both internal and external) are correctly and securely 
reassembled.
Indicated
% Power
Notes
0
0
Off
L*
1.5
Keep Warm
1
3
-
2
5.5
-
2.5
8
-
3
10.5
-
3.5
13
-
4
15.5
-
4.5
18
-
5
21
-
5.5
25
-
6
31
-
6.5
38
-
7
45
-
8
64
-
9
100
-
Pb
125-141
Boost
PLAQUETTE D'INTERFACE 
DE UTILISATEUR
PANNEAU TACTILE
CORE MAGNETIQUE
(4 TOURS)
ALIMENTATION ÉLECTRIQUE
INDUCTOR-ARRIÈRE GAUCHE
INDUCTOR-AVANT GAUCHE
INDUCTOR-ARRIÈRE DROITE
INDUCTOR-AVANT DROIT
BC
3
 TO USER INTERFACE BOARD
Á PLAQUETTE D'INTERFACE DE UTILISATEUR
THERMAL CUT-OUT
COUPE-CIRCUIT THERMIQUE
GENERATOR BOARD 1
CARTE GENERATEUR 1
GENERATOR BOARD 2
CARTE GENERATEUR 2
BC3
B81
BC4
B71
TAB1
TAB2
BC1
TAB102
TAB101
BC5
BPL1
BPL2
BPN2
BPN1
BPE03
BC3
B81
BC4
B71
TAB1
TAB2
BC1
TAB102
TAB101
BC5
BPL1
BPL2
BPN2
BPN1
BPE03
THERMAL CUT-OUT
COUPE-CIRCUIT THERMIQUE
ID JUMPER: ADDRESS 2
CONNECT BLACK JUMPER TO BC1
IDENTIFICATEUR: ADRESSE 2
BRANCHEZ EN UTILISANT FAISCEAU-FIL NOIR BC1
ID JUMPER: ADDRESS 1
DO NOT CONNECT BC1
IDENTIFICATEUR: ADRESSE 2 NE PAS BRANCHER BC1
Electronic Surface Element Control (ESEC)
This cooktop is equipped with an Electronic Surface Element Control (ESEC), 
which precisely controls the smoothtop cooking elements at multiple settings. For 
the user, the elements are operated by pressing the touch pads located on the 
control panel for the desired settings.  The control settings are shown in 2-digit 
displays.
Hot Surface display message - If any of the induction elements are hot, the hot 
surface message (HE) will display and remain ON until the cooktop cools.
ESEC lockout feature   - The Cooktop Lockout features will not operate when 
a surface element is ON.  Conversely, the surface elements controlled by the 
ESEC will not operate when Cooktop Lockout mode is active.  When the control is 
in Cooktop Lockout mode,   will appear in the display to signify that the surface 
heating elements are locked out.   
Replacing an induction element
Whenever replacing any induction element use only the screws supplied with the 
range to secure the element to the mounting panel. Never use any other type of 
screw to attach the induction element.
* Please note: Electronic boards are very sensitive to static electricity. Static elec-
tricity can permanently damage electronic boards. Before handling these parts, be 
sure to drain static electricity from your body by properly grounding yourself.