Electrolux EI30GF45QS インストール手順

ページ / 32
6
30" GAS RANGE INSTALLATION INSTRUCTIONS
2.2
 Provide an adequate gas Supply
When shipped from the factory, this unit is designed 
to operate on 4" (10,16 cm) water column (1,0 kPa) 
Natural gas manifold pressure. A convertible pressure 
regulator is connected to the range manifold and 
MUST be connected in series with the gas supply line. 
If LP/Propane conversion kit has been used, follow 
instructions provided with the kit for converting the 
pressure regulator to LP/Propane use.
Care must be taken during installation of range not to 
obstruct the flow of combustion and ventilation air.
For proper operation, the maximum inlet pressure to 
the regulator should be no more than 14" (35,56 cm) 
of water column pressure (3,5 kPa). The inlet pressure 
to the regulator must be at least 1" (0,25 kPa) greater 
than the regulator manifold pressure setting. Examples: 
If regulator is set for natural gas 4" (10,16 cm) manifold 
pressure, inlet pressure must be at least 5" (12,60 cm); 
if regulator has been converted for LP/Propane gas 10" 
(25,4 cm) manifold pressure, inlet pressure must be at 
least 11" (27,9 cm).
Leak testing of the appliance shall be conducted 
according to the instructions in step 4H.
The gas supply line should be ½" or ¾" I.D.
3
 Seal the openings
Seal any openings in the floor under the range after 
gas supply line is installed.
2.1
 gas and Electric Entry Preparation
•  The hatched areas are the locations where the gas
line can enter the cabinet (figure 5a).
•  The recommended position for the gas entry line is
located at 7" (17,8 cm) from the left cabinet wall and 
2" (5,1 cm) from the floor (figure 5a).
•  The shaded area is the location where the electric
outlet can be located (figure 5a).
If you are using a through the floor gas entry, 
remove the line protector shield
 from the bottom of 
the unit to allow access for the pipe line (figure 5b).
We recommend to install a pipe elbow right out of
the floor or wall towards the center of the unit to 
ease the installation.
5
3
4
5
4.5
11
3
6
W
ALL
W
ALL
2
2
30
(76.2)
(5.1)
(5.1)
12
(30.5)
Recommended 
position
Note: All dimensions are in inches (centimeter).
Figure 5a
To remove the line protector, remove the 3 screws.
Figure 5b
Gas pressure regulator location