Mount Main Housing to Structure
When mounting the Main Blower Housing, the (4) 
lag bolts must be attached to joists or studs, or 
other structural members. When mounting the main 
blower housing between fl oor joists or walls studs, 
it is necessary to space the blower housing off the 
fl oor or wall using a minimum 2x4 wood spacer. The 
wood spacers should be properly secured to the joists 
or studs. DO NOT secure the wood spacers to the 
sub-fl oor or wall materials.
Make the required electrical connections according 
to the attached wiring diagram.
When mounting the main blower housing, be sure 
to fully engage the inlet collar of the blower with the 
round duct inlet from the downdraft ventilation unit. 
Secure the outlet to the exhaust duct.
All duct connections should be sealed with duct tape 
and secured with screws.
Connect the Romex cable from the downdraft 
ventilation unit to the main blower housing.
DO NOT mount the main blower housing directly to 
sub-fl ooring or wall materials, this will not support 
the remote blower housing correctly.
When mounting the unit, do not warp or bend 
the housing, or mount in such a manner that the 
connected ductwork causes the housing to fl ex.
Before making any electrical connections, verify 
that the blower wheel spins freely.
Inlet
Inlet
Joist
or Stud
Flooring
or Wall
16”
(40.6 cm)
Over 16”
(40.6 cm)
1/4” Lag Bolts
1/4” Lag Bolts
Main
Blower
Housing
Cross Brace
or Cleat
Bracket
Mounting on Joists or Studs
Spaced 16”
Mounting Between Joists or Studs
Spaced More Than16”