30" Over-the-Range Microwave Specifications
•
Product Weight – 69 Lbs.
•
Voltage Rating – 120V / 60 Hz / 20 Amp
•
Connected Load (kW Rating) @ 120 Volts = 1.65 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
•
Amps @ 120 Volts = 15 Amps
•
Always consult local and national electric codes.
•
Grounded outlet should be located in cabinet above, with hole in base
to route power cord. Carefully follow top template instructions for power
cord clearance when installing beneath smooth, flat cabinets.
•
Microwave’s ventilation system is preset to recirculate air inside with
no ducting system required. Exhausting air outside is optional, using
either vertical or horizontal ducting system. (Refer to Ducted Option
Specifications for outside ventilation.)
•
For safe and proper installation, microwave MUST be mounted to
BOTH a top cabinet AND a wall, and connected to at least one wall stud.
Can NOT be installed in island or peninsula cabinet arrangements.
•
Cabinet bottom MUST be level to insure proper installation.
•
Cabinet MUST be capable of supporting a total load of 150 lbs.
•
Filler blocks recommended for installation when cabinet front hangs below
recessed bottom shelf.
•
Minimum distance of 30" required from cooking surface to bottom
edge of top cabinet.
•
Minimum distance of 66" required from floor to top of microwave.
•
Opening between cabinets MUST be 30" wide and free of obstructions.
•
Allow 25-1/2" minimum clearance for 90° door swing.
Ducted Option Specifications
•
For outside ventilation.
•
Exhaust duct adapter supplied assembled for outside ventilation,
designed to mate with standard 3-1/4" x 10" rectangular duct. If round
duct required, rectangular-to-round transition adapter will be needed
with 5" / 6" diameter.
•
For most efficient airflow exhaust, use a straight run or as few elbows as
possible with maximum duct length of 3-1/4" x 10" rectangular or 5" / 6"
diameter round duct, not to exceed 120 equivalent feet.
•
For horizontal installation, be sure to allow enough space between wall
studs to accommodate exhaust.
•
Refer to installation instructions on web for detailed duct preparation and
converting exhaust vent blower system for exterior exhaust ventilation.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxicon.com for detailed instructions.
Optional Accessories
•
36" Filler Panel Kit – (PN # MWFILKTSS).
E30MH65QP 05/14
© 2014 Electrolux Home Products, Inc.
*Can NOT be installed in island
or peninsula cabinet arrangements
†
If cabinet depth including cabinet doors
is greater than 13", then unit needs
spaced out from wall using adequate
materials capable of supporting a total
load of 150 lbs., to allow for proper
top vent air exhaust
16
3
/
8
"
29
7
/
8
"
14
3
/
8
"
Blower plate allows for vertical
or horizontal ducting
Power cord location
(right top rear)
17
9
/
16
"
1
/
2
" lower
extrusion
Allow at least 25
1
/
2
" clearance
for door depth when open
17
1
/
16
"
Over-the-Range Microwave
E30MH65QPS
Electrolux ICON
Backsplash
Rear Wall
17
1
/
2
"
min.
30" min.
66" min.
from floor
to top of
microwave
Bottom edge of
cabinet MUST be
30" min. from
cooking surface
Cabinet MUST
be capable of
supporting a total
load of 150 lbs.
30"
min.
Microwave MUST
be mounted to
BOTH a top cabinet
AND a wall*
Locate 120V/60Hz grounded outlet inside upper cabinet
13"
max.
†
2" min.