Electrolux E30IC75FSS インストール手順

ページ / 16
1
INDUCTION COOKTOP INSTALLATION INSTRUCTIONS
30” Min. *
(76.2 cm)
B
C
A
I
F
D
G
H
E
All dimensions are stated in inches and (cm).
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
WARNING
 FOR YOUR SAFETY:  Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
IMPORTANT INSTALLATION INFORMATION
• All electric cooktops run off a single phase, three-wire or four-wire cable, 240/208 volt, 60 hertz, AC only
electrical supply with ground.
• Minimum distance between cooktop and overhead cabinetry is 30" (76.2 cm).
Cooktop Dimensions
* 30" (76.2 cm) min. for
unprotected cabinet and
24" (61 cm) min. for cabinet
with protected bottom surface.
** Do not obstruct these areas.
Cooktop Cutout Dimensions
Printed in United States
 P/N 318201430 (0809) Rev. E
English – pages 1-5
Español – pages 6-10
Français - pages 11-16
4" X 8" (10.2 cm x 20.3 cm)
opening to route armored cable if
a panel is present.
Fresh air intake**
Air exhaust**
Fresh air intake**
Figure 1
B. DEPTH
21½ (54.6)
A. WIDTH
30¾ (78.1)
COOKTOP DIMENSIONS
G. WIDTH
I. HEIGHT
4½ (11.4)
H. DEPTH
CUTOUT DIMENSIONS
F. DEPTH
19
7
/
8
 (50.5)
E.WIDTH
28
7
/
8
 (73.3)
D
2¾ (7)
C
2 (5.1)
Min.
29
5
/
8
 (75.2)
Max.
29¾ (75.6)
Min.
20
3
/
8
 (51.8)
Max.
20½ (52.1)
HEIGHT