30" GAS RANGE INSTALLATION INSTRUCTIONS
Shutoff Valve -
Open position
to appliance
to gas suppl
y line
Figure 5
Use pipe-joint compound made for use with Natural and
LP/Propane gas to seal all gas connections. If flexible 
connectors are used, be certain connectors are not 
kinked.
The supply line must be equipped with an approved 
manual shutoff valve. This valve should be located in 
the same room as the range and should be in a location 
that allows ease of opening and closing. Do not block 
access to the shutoff valve. The valve is for turning on or 
shutting off gas to the appliance.
Once regulator is in place, open the shutoff valve in the 
gas supply line. Wait a few minutes for gas to move 
through the gas line.
Check for leaks. After connecting the range to the gas 
supply, check the system for leaks with a manometer. 
If a manometer is not available, turn on the gas supply 
and use a liquid leak detector (or soap and water) at all 
joints and connections to check for leaks. Leaks will be
indicated by bubbles appearing at the connections or 
joints.
Assemble the flexible connector from the gas supply pipe 
to the pressure regulator in the following order:
1.  Manual shut-off valve (not supplied)
2.  1/2" nipple (not supplied)
3.  1/2" flare union adapter (not supplied)
4.  Flexible connector (not supplied)
5.  1/2" flare union adapter (not supplied)
6.  1/2" nipple (not supplied)
7.  Pressure regulator (supplied)
3.
 Gas Supply Installation
When shipped from the factory, this unit is designed 
to operate on 4"(10,16 cm) water column (1.0 kPa) 
Natural gas manifold pressure. A convertible pressure 
regulator is connected to the range manifold and MUST 
be connected in series with the gas supply line. The gas 
connector is located as shown on figure 2. It is accessible 
from front of the range.
For proper operation, the maximum inlet pressure to 
the regulator should be no more than 14"(35,56 cm) of 
water column pressure (3.5 kPa). 
The inlet pressure to the regulator must be at least 1" 
(.25 kPa) greater than the regulator manifold pressure 
setting. The regulator is set for 4"(10,16 cm) water 
column (1.0 kPa) Natural gas manifold pressure; the inlet 
pressure must be at least 5"(12.60 cm) water column 
(1.25 kPa) Natural gas. For LP/Propane gas, the regulator 
must be set for 10"(25,4 cm) water column (2.5 kPa) 
manifold pressure; the inlet pressure must be at least 
11"(27,9 cm) water column (2.75 kPa).
The supply line should be equipped with an approved 
shutoff valve (see Figure 4 and 5). This valve should be 
located in the same room as the range and should be 
in a location that allows ease of opening and closing. 
Do not block access to the shutoff valve. The valve is for 
turning on or shutting off gas to the appliance. Open the 
shutoff valve in the gas supply line. Wait a few minutes 
for gas to move through the gas line.
The gas supply between the shutoff valve and the 
regulator may be connected by rigid piping or by CSA-
approved flexible metallic union-connected piping where 
local codes permit use.
The gas supply piping can be through the side wall of 
the right cabinet. The left side cabinet is an ideal location 
for the main shutoff valve, if the range is installed within 
cabinet storage space
Connection to Pressure Regulator
The regulator is already installed on the appliance.
 Do not make the connection too tight. 
The regulator is die cast. Overtightening may crack the 
regulator resulting in a gas leak and possible fire or 
explosion.
The gas supply line to the shutoff valve should be 
1/2"(1,27 cm) or 3/4"(1.9 cm) solid pipe.
The user must know the location of the main shutoff 
valve and have easy access to it.
When using flexible gas conduit on the range, allow 
sufficient slack to pull the range outside the cutout for 
cleaning or servicing.
NOTE:  Do not allow the flexible conduit to get pinched 
between the wall and the range. 
All connections must be wrench-tightened
Figure 4
Flare
Union
Flare
Union
GAS FLOW
Manual
Shutoff
Valve
Pressure
Regulator
On
Off
Flexible
Connector
Access
Cap
Nipple
Nipple
Suggested gas connection