Electrolux EP19WI30LS オーナーマニュアル

ページ / 38
20
Preventing Damage from Freezing-3
For EN19WI30LS, EP19WI30LS
Drain Plugs
Each drain plug might not be visible if 
insulation is installed around the piping.
If the water heater will not be used for a long period of time, drain the water.
Drain the water as follows:
To avoid burns, wait until the equipment cools down 
before draining the water.  The appliance will remain 
hot after it is turned off.
High Temperature
CAUTION
Fully open all hot water fixtures.
4
Open all drain plugs and drain the water out of 
the unit.
1
Close the water supply 
valve.
6
Close the gas valve and disconnect 
the electrical power supplied to the unit.
2
3
Fully open all 
hot water fixtures.
Fixture
Drainage Using the Remote Controller
2
5VSOUIFQPXFSPOPGGCVUUPOi0Ou
(2)   Turn and leave open 
 
the hot water fixtures 
 
for more than 2 minutes 
 and 
close.
* If multiple units are being used, 
drain two minutes for each unit.
* An 11 Error Code may appear on 
the remote controller.
  This is not a malfunction of the unit. 
 %POPUUVSO1PXFS0/0''#VUUPO0''
Manual Draining
Close the water supply 
valve and disconnect 
the electrical power 
supplied to the unit.
3
4
5
When the water is completely drained, replace 
all drain plugs and close the hot water fixtures.
5
Open all drain plugs and drain the 
water out of the unit.
6
Close the gas valve. 
1
W h e n  t h e  w a t e r  i s  c o m p l e t e l y 
drained, replace all drain plugs and 
close the hot water fixtures.
Fixture
Fixture
(Ex. 120°F)
Do not touch with wet hands.
Do not touch with wet hands.
Drain water into a bucket to prevent water damage.
 5VSOUIFQPXFSPOPGG
CVUUPOiPGGu
(2) Press the flow meter alarm set 
button for about two seconds 
until the alarm sounds.
 
The maximum hot water 
temperature  will flash. 
(3) Press the flow meter alarm 
set button again.
(4) Press the setting button 
NBSLFEiu. The display will 
DIBOHFGSPNP'UPPOBGUFS
the button is pushed.