Electrolux UR15IM20RS オーナーマニュアル

ページ / 29
23
Maintenance
DRAIN PUMP REMOVAL 
INSTRUCTIONS  
(FOR SERVICE ONLY)
  1.  Unplug the ice machine from the 
electrical supply and remove the rear 
access cover from the ice machine. 
  2.  Unscrew the leveling leg in the back 
corner until the end of the threaded 
portion is flush with the threaded nut 
insert in the base (Figure 8). 
  3.  Unscrew the 3 hose clamps and 
remove the 3 hoses from the front of 
the drain pump and remove retaining 
brackets (Figure 8).
  4.  Rotate the drain pump and remove 
from the ice machine (Figure 7). It 
may be necessary to disconnect the 
ground wire connection in the back 
flange of the cabinet (Figure 8).
Figure 8
Unscrew the leveling
leg so the end of the 
threads is flush with 
the top of the nut inset.
Drain pump
ground wire
connection
Remove these 3 
hose clamps, then 
remove the 3 tubes 
from the drain pump
Figure 7
Rotate drain pump and remove from
back of ice machine.
Drain valve
Additional issues to be inspected 
by the installer upon service 
replacement:
  1.  The drain pump must be level.
  2.  No pinched water lines.
  3.  No interference with electrical cords 
or wiring.
  4.  The drain pump should not set on 
any obstacles, wiring, etc.
  5.  Secure all hose clamps leading to 
and from the drain pump.
  6.  Ensure that the vent tube height is 
adequate - 18 inch minimum.
  7.  Ensure that drain height is adequate - 
maximum of 8 foot.
  8.  Ensure that drain length is adequate - 
maximum of 20 foot.
  9.  Checked for water leaks after 
installation of the drain pump.
 10.  Check for vibrations caused by 
improper installation.
 11.  Ensure that there is no interference 
with back access cover.
 12.  Ensure that the hole grommets are 
in place at each location so that any 
vent or drain tubes do not rub on any 
sharp surfaces.
Figure 9
Ice Machine
Power Cord
  5.  Disconnect the ice machine power cord 
from the drain pump (Figure 9).
  6.  Drain the water in the drain pump’s 
reservoir by turning the pump upside 
down and allowing water to drain 
through the pump’s inlet and vent 
tube fittings.
  7.  Installation of drain pump is reverse 
of this procedure.