Installation
Installation Dimensions
24"
(61cm)
21 3/4"
(55.2cm)
Water
Valve
5"
(12.7cm)
33 5/8"
(85.4cm)
Adjustable
to 34 3/4"
(88.3cm)
Water
Drain
Water
Outlet
14 7/8"
(37.8cm)
Figure 3
Factory Installed Drain Pump
This pump is designed to remove drain water from ice machines installed in areas without 
direct drainage access. The sealed reservoir pump collects the melted ice water and pumps 
it to a maximum lift of eight feet (2.44 meters) through 3⁄8” I.D. vinyl tubing to a drain.
The discharge tubing is coiled up and attached to the back of the ice machine. The 3⁄8 
inch I.D. tubing needs to be plumbed and connected to a sanitary sewer (Figure 4).
CAUTION
This drain pump is designed to be 
installed in Electrolux ice machines 
only and has been evaluated for use 
with water only. Drain line vertical rise 
is not to exceed 8 feet and total drain 
line length is not to exceed 20 feet; 
otherwise, the ice machine may not 
operate correctly.
WARNING
Electrical Shock Hazard
Risk of electrical shock or personal injury 
could occur due to moving components, 
if the machine compartment access 
cover is removed before unplugging the 
ice machine power cord.
Figure 4
Drain line coiled and
secured to the back of the 
cabinet. Uncoil, route to 
an appropriate drain and 
cut to length.
Drain pump
vent tube. Keep 
this open to assure 
air flows freely as 
water enters the 
pump reservoir.