Philips BDL4620QL/00 ユーザーズマニュアル

ページ / 30
BDL4620QL
v
Polish Center for Testing and Certification 
Notice
The equipment should draw power from a socket with an attached 
protection circuit (a three-prong socket). All equipment that works 
together (computer, display, printer, and so on) should have the same 
power supply source.
The phasing conductor of the room’s electrical installation should have 
a reserve short-circuit protection device in the form of a fuse with a 
nominal value no larger than 16 amperes (A).
To completely switch off the equipment, the power supply cable must 
be removed from the power supply socket, which should be located 
near the equipment and easily accessible.
A protection mark “B” confirms that the equipment is in compliance 
with the protection usage requirements of standards PN-93/T-42107 
and PN-89/E-06251.
Electric, Magnetic and Electronmagnetic 
Fields (“EMF”)
1.  We manufacture and sell many products targeted at consumers, 
which, like any electronic apparatus, in general have the ability to 
emit and receive electromagnetic signals.
2.  One of our leading Business Principles is to take all necessary health 
and safety measures for our products, to comply with all applicable 
legal requirements and to stay well within the EMF standards 
applicable at the time of producing the products.
3.  We are committed to develop, produce and market products that 
cause no adverse health effects.
4.  We confirm that if its products are handled properly for their 
intended use, they are safe to use according to scientific evidence 
available today.
5.  We play an active role in the development of international EMF and 
safety standards, enabling us to anticipate further developments in 
standardization for early integration in its products.
Information for U.K. only
WARNING – THIS APPLIANCE MUST BE EARTHED.
Important:
(A)
(B)
This apparatus is supplied with an approved moulded 13A plug. To 
change a fuse in this type of plug proceed as follows:
1.  Remove fuse cover and fuse.
2.  Fit new fuse which should be a BS 1362 5A,A.S.T.A. or BSI approved 
type.
3.  Refit the fuse cover.
If the fitted plug is not suitable for your socket outlets, it should be cut 
off and an appropriate 3-pin plug fitted in its place.
If the mains plug contains a fuse, this should have a value of 5A. If a plug 
without a fuse is used, the fuse at the distribution board should not be 
greater than 5A.
NOTE:   The severed plug must be destroyed to avoid a possible shock 
hazard should it be inserted into a 13A socket elsewhere.
How to connect a plug
The wires in the mains lead are coloured in accordance with the 
following code:
BLUE – “NEUTRAL” (“N”)
BROWN – “LIVE” (“L”)
GREEN & YELLOW – “EARTH” (“E”)
1.  The GREEN & YELLOW wire must be connected to the terminal in 
the plug which is marked with the letter “E” or by the Earth symbol 
or coloured GREEN or GREEN & YELLOW.
2.  The BLUE wire must be connected to the terminal which is marked 
with the letter “N” or coloured BLACK.
3.  The BROWN wire must be connected to the terminal which 
marked with the letter “L” or coloured RED.
Before replacing the plug cover, make certain that the cord grip is 
clamped over the sheath of the lead – not simply over the three wires.