Sterling 882.00379.00 ユーザーズマニュアル

ページ / 138
Conveying System Mechanical Components    Chapter 3: Installation 
52 of 138 
Figure 26:  Typical Single Line Y-Tube System Installation 
 
 
 
 
Material Check Valves in Single Line Y-Tube Systems 
  Check valves are a critical feature on single line Y systems. You must have a check 
valve installed on the material inlet inside the receiver on all vacuum hoppers in single 
line Y installations. 
  Check valves must open when the receiver is being loaded and seal to prevent a 
vacuum leak when other hoppers are being loaded. 
  Vacuum receivers for these systems have a special factory-installed extended material 
inlet tube to hold the check valve. 
  The check valve must not be pressed too far onto the inlet stub to prevent proper 
sealing. 
  The hinge of the check valve should be up to prevent material from being deflected up 
into the vacuum hopper filter. 
  Do not allow vacuum receivers with check valves to be over-filled to a point above the 
bottom of the check valve. Over-filling prevents the check valve from sealing and 
creates a vacuum loss. Adjust the conveying time on Time-Fill systems to prevent this 
from happening. 
  Inspect periodically for erosion or wear. Replace as required.