Sterling 882.00379.00 ユーザーズマニュアル
Conveying System Mechanical Components Chapter 3: Installation
52 of 138
Figure 26: Typical Single Line Y-Tube System Installation
Material Check Valves in Single Line Y-Tube Systems
•
Check valves are a critical feature on single line Y systems. You must have a check
valve installed on the material inlet inside the receiver on all vacuum hoppers in single
line Y installations.
line Y installations.
•
Check valves must open when the receiver is being loaded and seal to prevent a
vacuum leak when other hoppers are being loaded.
•
Vacuum receivers for these systems have a special factory-installed extended material
inlet tube to hold the check valve.
•
The check valve must not be pressed too far onto the inlet stub to prevent proper
sealing.
•
The hinge of the check valve should be up to prevent material from being deflected up
into the vacuum hopper filter.
•
Do not allow vacuum receivers with check valves to be over-filled to a point above the
bottom of the check valve. Over-filling prevents the check valve from sealing and
creates a vacuum loss. Adjust the conveying time on Time-Fill systems to prevent this
from happening.
creates a vacuum loss. Adjust the conveying time on Time-Fill systems to prevent this
from happening.
•
Inspect periodically for erosion or wear. Replace as required.