Electrolux 111 K ユーザーズマニュアル

ページ / 16
16
Wiring diagram
Connection
Min. size
Cable / flex
Fuse
via
Cable/flex
type
• Cooker
6 mm
2
PVC/PVC
30 A
Control
twin and
Circuit
earth
For Uk use only
For Europe use only
Min. size Cable/flex
Cable / flex type
Fuse
2.5 mm
2
H05 RR-F
30 A
Permanent Connection
In the case of a permanent connection, it is necessary that you install a double pole switch
between the hob and the electricity supply (mains), with a minimum gap of 3 mm. between
the switch contacts and of a type suitable for the required load in compliance with the current
electric regulations.
The switch must not break the yellow and green earth cable at any point.
Ensure that the hob supply cord does not come into contact with surfaces with temperatures
higher than 50 deg. C.
Supply Cable Specifications
4 3 2 1
4
3
1
2
5
P
2
P
1
P
3
1
4 3 2 1
4
3
1
2
5
P
2
P
1
P
3
2
4 3 2 1
4
3
1
2
5
P
2
P
1
P
3
3
4 3 2 1
4
3
1
2
5
P
2
P
1
P
3
4
PLATE
Ø 180
Ø 180 R
Ø 145 R
Ø 145
N
L
L
4
1
3