When positioning your Router, ensure:
It is out of direct sunlight and away from sources of heat.
Cabling is away from power lines, fluorescent lighting fixtures, and 
sources of electrical noise such as radios, transmitters and broadband 
amplifiers.
Water or moisture cannot enter the case of the unit.
Air flow around the unit and through the vents in the side of the case 
is not restricted. 3Com recommends you provide a minimum of 
25 mm (1 in.) clearance.
Using the Rubber
Feet
Use the four self-adhesive rubber feet to prevent your Router from 
moving around on your desk or when stacking with other flat top 
OfficeConnect units. Only stick the feet to the marked areas at each 
corner of the underside of your Router.
Stacking the Router
If you are stacking your Router with other OfficeConnect units, install the 
Router at the top of the stack. Refer to the documentation supplied with 
your other OfficeConnect unit for details on using the stacking clip.
A stacking clip is not supplied with the Router. Use the stacking clip 
supplied with another stackable OfficeConnect unit.
Wall Mounting
There are two slots on the underside of the Router that can be used for 
wall mounting. 
When wall mounting the unit, ensure that it is within reach of the power 
outlet.
Do not install the Router more than 200 cm above the ground.
You will need two suitable screws to wall mount the unit. To do this:
Ensure that the wall you use is smooth, flat, dry and sturdy and make two 
screw holes which are 150 mm (5.9 in.) apart.
Fix the screws into the wall, leaving their heads 3 mm (0.12 in.) clear of 
the wall surface.
Remove any connections to the unit and locate it over the screw heads. 
When in line, gently push the unit on to the wall and move it downwards 
to secure.