Meridian Data 16i ユーザーズマニュアル

ページ / 91
Chapter 1 Introduction 
 
 
 
 
 
 
 
 
 
1-5 
 
•   BBU module: An optional BBU module sustains 
unfinished writes cached in memory during a power 
outage in order to prevent data loss. (See Section 0) 
•  PSU modules: The hot-swappable PSUs receive single-
phase power and deliver +5V, +12V, and +3.3V power to 
the subsystem. A power switch is located on each PSU to 
turn the system on and off. (See Section 0) 
•  Cooling modules: The redundant cooling modules 
ventilate the subsystem to maintain a cooling airflow 
across the subsystem. (See Section 0) 
 
1.1.2.6 Backplane 
Board 
An internal backplane board separates the front and rear sections of the 
SecurStor 16I. The PCB board consists of traces for logic level signals and 
low voltage power paths. It contains no user-serviceable components.   
 
 WARNING! 
When inserting a removable module, DO NOT USE EXCESSIVE 
FORCE! Forcing or slamming a module can damage the pins on the 
module connectors either on the module itself or on the backplane. Gently 
push the module until it reaches the end of module slot.  Feel the contact 
resistance and use slightly more pressure to ensure the module connectors 
are correctly mated. If the module comes with ejection levers or retention 
screws, use them to secure the module.    
 
1.2 Subsystem 
Components 
The SecurStor 16I houses many active components and most of them can be accessed 
through either the front or rear panel. The modular design of the active components 
facilitates their easy installation and removal. Hot-swap mechanisms are incorporated 
to eliminate power surges and signal glitches that might occur while removing or 