DCT3080 Installation Manual 
 
34 
ƒ
  When the LED display is blank, the terminal is ready for initialization 
and service authorization using the addressable controller. Verify that 
the terminal is powered up or reset within two minutes of a 
completed download. 
Boot Cycle Error Codes 
If hardware or software problems occur, the terminal displays error 
codes on the LED display. 
125H
Table 2-5 lists error codes that can occur 
during boot cycle startup: 
Table 2-5  
Boot cycle error codes 
Code  Description 
When Error Occurs 
Action Required 
Eb 
01 
Object failed 
validation 
After the LED displays dl, 
indicating validation check 
failed 
Contact headend 
operator 
Eb 
02 
Download 
time-out 
After cycling twice through the 
OOB frequencies 
None 
Eb 
03 
Flash erase 
failed 
After software object 
download complete and EF is 
displayed  
Replace the terminal 
Eb 
04 
Flash 
programming 
failed 
After software object 
download complete and FP is 
displayed 
Contact headend 
operator 
Eb 
05 
Invalid DLC 
frequency 
After the LED displays dl, 
indicating validation check 
failed 
Contact headend 
operator 
Eb 
06 
Hardware 
initialization 
failed 
After plugging the terminal 
into an electrical outlet to 
begin the boot cycle 
Replace the terminal