Motorola DCT3080 ユーザーズマニュアル

ページ / 98
DCT3080 Installation Manual 
 
49 
Figure 3-5  
LED display for in-band diagnostic 
MUTE
MUTE
P
IB diagnostic
indicator
Data activity indicator
Carrier lock indicator
(L = locked, U = unlocked)
 
The In-Band Status fields are: 
Field Description 
Mode 
The values displayed on the OSD are:  
ƒ
 
64 QAM — 64 QAM digital channel 
ƒ
 
256 QAM — 256 QAM digital channel 
Carrier 
Lock 
Indicates whether the in-band receiver is locked to the carrier. If a 
digital carrier is not present, it indicates the carrier is not locked: 
 OSD 
LED 
Description 
 
YES L 
Carrier 
locked 
 
NO 
Carrier not locked 
Data 
Indicates whether data is being carried on the in-band stream. 
The indicators cover all packet processors, regardless of the 
stream they are monitoring: 
 OSD 
LED 
Description 
 
YES  On 
In-band data detected within last 5 seconds 
 
NO 
Off 
In-band data not detected within last 5 seconds 
SNR 
When carrier lock has been established, displays an estimate of 
the carrier signal-to-noise ratio in dB, with an explanation: 
ƒ
 
GOOD — Good value 
ƒ
 
FAIR — Marginal signal level; check the signal 
ƒ
 
POOR — Unusable signal 
ƒ
 
INVALID — Invalid SNR value