Field Description 
State 
The interactive status of the DCT3080: 
 
LED            OSD 
Description 
   
UNCONFIG 
The DCT3080 is not 
configured for the interactive 
system, and, platform should 
run as pre-interactive. 
 
MAC_CONNECT 
The DCT3080 is waiting to 
establish connection to MAC 
PID Stream. 
 
I dc 
INIT_WAIT_DC_OR_C 
The DCT3080 is in the 
interactive initialization state 
and waiting for the default 
configuration or the contention 
channel list messages. 
 
I L 
WAIT_LM_ACK 
The DCT3080 is in the 
interactive initialization state 
and waiting for Link 
Management Response ACK 
for Local Address Message. 
 

SO 
WAIT_SO_ACK 
The DCT3080 is in the 
interactive initialization state 
and waiting for a Sign On 
acknowledgement. 
 
I LA 
WAIT_LA_OR_SO  
The DCT3080 is in the 
interactive initialization state 
and waiting for Logical 
Address or Sign On with 
verification Frequency 
message. 
 
S I 
INIT_STOPPED 
The DCT3080 is in the 
interactive initialization state, 
and the TransMode has 
stopped. 
 
r dc 
RUN_WAIT_DC_OR_C  The DCT3080 is in the 
interactive state and waiting for 
the default configuration or the 
contention channel list 
messages.