Omega Vehicle Security OM-550 ユーザーズマニュアル

ページ / 84
OM-550
u
6
u
••
 RUN
The RUN key activates the OM-550 to begin logging. The data is stored in internal
memory, optionally printed, and can be transferred to a PC at a later time. When the
RUN key is pressed, the messages shown in Figure 2-8 are displayed.
Figure 2-8
This printout shows the pressed key (RUN), and how often the inputs will be sampled
as HH:MM:SS (hours, minutes, seconds), shows the time required to fill the data cache
as DDDD:HH:MM:SS (days, hours, minutes, seconds), indicates that the unit is
programmed to automatically stop when the cache is full, and asks if the data should be
printed during logging (refer to section 4.7 OPERATION AT FULL CACHE
(RECORDING TIME)
).
Pressing the YES key will activate the OM-550 to begin collecting data for all active
channels (those not programmed as SKIP). The inputs will be sampled at the preset log
interval and the data will be printed and saved to the cache. If the log interval is greater
than 1 minute, the unit will turn “OFF” (Power save mode) between scans to save
battery power.
If the NO key is pressed, data will still be collected and saved to the data cache, but not
printed. This will save power and paper allowing the unit to log at shorter log interval
settings. Only the statistics will print when the STOP key is pressed. The data can, of
course, be printed after it is transferred to a PC.