Initial Settings
NOTE: 
Installing a shunt or jumper on the pins will activate the feature.
CONTROL BOARD SETUP
“Fail Safe/Secure”
During complete power 
failure, including battery 
power; determines the force 
required to manually move 
the gate.
• Fail Safe Mode:
By removing the wire-
jumper plug from the “Fail 
Safe/Secure” connector:
The gate can move 
manually with a relatively 
low amount of force.
• Fail Secure Mode:
By inserting the wire-
jumper plug into the “Fail 
Safe/Secure” connector:
The gate will not move 
manually.
!
 
IMPORTANT:
 
Regardless of the power failure options chosen, the gate can be moved 
manually with a relatively low amount of force by following the steps for “Manual 
Release” as outlined at on page 11.
“Sync” 
Used only in conjunction with 
the Viking Barrier gate operator model 
B-12. Activating this feature allows for 
synchronized operation with the B-12 
operator. See page 35.
“Auto Open” - Power Failure Option
Opens the gate automatically during 
power failure. Resumes normal operation 
when power is restored.
“Pre-Warning”
 Initiates two options for 
an audio or visual warning 3 seconds 
prior to gate motion and will continue:
1.  Until gate reaches closed limit: 
“Magnetic Lock” terminals provide a 
contact between “COM” and “N.O”.
2. Until gate reaches either limit:  
“AUX. PWR” terminals provide 24VDC.
“EXT” 
Available for future developments.
“Last Open” - Power Failure Option
Opens the gate automatically when the 
battery backup voltage is critically low.