Multiquip MGX ユーザーズマニュアル

ページ / 30
MgX SerieS • operaTion and parTS Manual — rev. #0 (03/26/12) — page 13
General infOrMatiOn
When determining which head to choose it is important 
to access the application. Mainly what are the dimensions 
of the application. Select the vibrator head based on its  
radiating radius characteristics. Reference Table 4.
Select the vibrating head that covers the largest possible 
area  without  excessive  overkill. This  will  allow  for  more 
efficient  productivity.  General  rule  of  thumb  is
 do noT 
select a vibrator head which has a vibration radius of more 
than twice the width of the form.
Example:
If the form width is 9 inches (229 mm) the selected vibrator 
head radius should not exceed an 18 inch (457 mm) radius. 
In this example the MGX3810 and MGX3825 head/shaft 
would be the recommended choice. Refer to Table 4 and 
Figure 3.
 NOTICE
Vibrator  head  spacing  distance  (
d) is calculated by 
multiplying  the  vibrating  head  radius  (
r)  (area  of 
influence) by 1.5.
 NOTICE
Vibration  techniques,  vibrator  head  placement  and 
spacing as referenced in the "General Information" and 
"Operation" sections of this manual is only to be
 used 
as a guideline. Multiquip assumes no responsibility for 
vibrator operating techniques referenced in this manual.
The  consolidation  of  concrete  has  many  mitigating 
factors that must be considered such as slump, mix, 
depth  of  vibrator,  vibrator  spacing,  vibration  time, 
vibration frequency, temperature. All of these factors 
must be considered when the consolidation (vibration) 
of concrete is required.
AREA OF INFLUENCE
(VIBRATING RADIUS)
VIBRATOR HEAD
INSERTION SPACING
VIBRATOR HEAD
INSERTION POINT
CONCRETE
TOO SMALL AREA
OF INFLUENCE
(VIBRATING RADIUS)
NO VIBRATION
NO VIBRATION
CORRECT
FORM
WIDTH
Figure 3. Head Selection