Linear BGUS-D ユーザーズマニュアル

ページ / 32
MODEL BGUS/BGUS-D • SG/SG-D OPERATOR INSTALLATION GUIDE
-8-
ELECTRICAL CONNECTION AND ADJUSTMENTS
All LINEAR gate operators are supplied with a power disconnect switch to turn on and off the power supply available to the 
operator. Incoming power should be brought into the operator and connected to the labeled pigtails in the disconnect box, 
following wiring specifi cations on Page 4. A wiring connections print can be found on the inside cover of the operator.
Proper thermal protection is supplied with the operator. The motor contains a thermal overload protector to protect from 
overheating the motor due to overload or high-frequency operation. This overload will reset automatically after the motor 
cools down.
Power supply must be of correct voltage and phase.
Always follow national and local electrical codes when wiring and use a 
qualifi ed electrician.
Always disconnect power from operator before servicing.
Keep clear of gate arm during operation.
VENT PLUG INSTALLATION
Gear reducers used in LINEAR gate operators will have pinned vent plugs installed prior to shipping in order to keep the 
oil from spilling out during transportation. During installation this pin should be removed to allow proper ventilation. See the 
illustrations below.
OR
The limit cams for all models of barrier gate operators have 
been pre-set at the factory for approximately 90 degrees of 
motion. If you need to adjust this further, please follow the 
directions below. If the arm reverses just after you attempt 
to open it, you may need to adjust the open direction current 
sensor one turn higher. Refer to Page for details of current 
sensing adjustment.
1. For 
more downward travel, loosen the wing nut on 
the LSC-1 (down) limit cam and rotate the cam slightly 
in the “B” direction.
2. For 
less downward travel, loosen the wing nut on the 
LSC-1 (down) limit cam and rotate the cam slightly in 
the “A” direction.
3. For 
more upward travel, loosen the wing nut on the 
LSO-1 (up) limit cam and rotate the cam slightly in the 
“A” direction.
4. For 
less upward travel, loosen the wing nut on the 
LSO-1 (up) limit cam and rotate the cam slightly in the 
“B” direction.
LIMIT CAM ADJUSTMENTS