Mitsubishi Electronics A1SD75M1/M2/M3 ユーザーズマニュアル

ページ / 212
 
 
 
11 - 32                                                                                                                                                       11 - 32 
MELSOFT
11. POSITIONING DEBUGGING 
 
DISPLAY/SETTING DATA
 
 
Item Description 
Start position 
Set the positioning data No. to the axis on which the positioning start test will be conducted. 
"#1 Start" button 
"#2 Start" button 
"#3 Start" button 
Click any button to start the start test of the corresponding axis to which the positioning data 
No. has been set. 
This button is invalid for the axis on which the positioning start test is being made. 
This button acts as the "Restart" button during a stop made with the external stop signal. 
Current value change 
request 
Set a new current value. 
"#1 Change req." button 
"#2 Change req." button 
"#3 Change req." button 
Click any button to change the current value. 
If the corresponding axis is operating, the current value change request is invalid. 
"#1 stop" button 
"#2 stop" button 
"#3 stop" button 
Click the corresponding button to stop the axis on which the positioning start test is being 
made. 
Reset the error after a stop since the axis results in an "Error Occurrence" status. 
"All stop" button 
Click this button to stop all operating axes. 
Reset the error after a stop since the axis results in an "Error Occurrence" status. 
"Error reset" button 
 / 
 / 
 ) 
Click any button to reset the error of the corresponding axis. 
"M code Off" button 
 / 
 / 
 ) 