Mitsubishi Electronics A1SD75M1/M2/M3 ユーザーズマニュアル
6 - 8 6 - 8
MELSOFT
6. PROJECT CREATION
6.5.2 Reading the CSV format file
PURPOSE
GX Configurator-AP allows CSV format files created with spreadsheet software or
the like to be read as positioning data (axis #1 to #3). (Parameters and start block
data cannot be read.)
The creating method and reading operation of CSV format data are described
below.
•
If all items that make up positioning data have not been entered, CSV format data
cannot be read, resulting in an error.
•
Since CSV format data is read axis-by-axis, create CSV format data noting which
axis (#1/#2/#3) data is being created.
(1) CSV format data creating method
The following sheet indicates the items and values of CSV format data set on a
column basis. It should be noted that you cannot set the interpolation axis and
circular addresses for interpolation control.
<Example of data set to spreadsheet software>
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
<Data set to the above spreadsheet software was read with
GX Configurator-AP >
Num
ber
ber
Setting
Remarks
1)
Line 1 from table top is positioning No. 1 data and line 2 is positioning No. 2 data.
2)
Set the positioning control pattern in column 1 from left. Set any value of 0 to 2.
3)
Set the control method in column 2 from left. Set it with 1 to 9 and A to I.
4)
Set the accel time in column 3 from left. Set it with 0 to 3.
5)
Set the decel time in column 4 from left. Set it with 0 to 3.
6)
Set the address in column 5 from left.
7)
Set the circular address in column 6 from left.
8)
Set the command speed in column 7 from left.
9)
Set the dwell time in column 8 from left.
10)
Set the M code in column 9 from left.
Refer to Section
9.1 for details of
data
corresponding to
values and
alphabets to be
set.