Mitsubishi Electronics AD75P1/P2/P3 ユーザーズマニュアル

ページ / 212
 
 
 
11 - 24                                                                                                                                                       11 - 24 
MELSOFT
11. POSITIONING DEBUGGING 
 
DISPLAY/SETTING SCREEN
 
 
1)
12)
13)
6)
7)
9)
10)
8)
11)
17)
16)
14)
 5)
15)
 
 
2)
3)
4)
 
 
DISPLAY/SETTING DATA
 
 
No. Item 
Description 
1) 
"Start Condition" button 
Click this button to display the Position data test set dialog box which is used to set 
the operating conditions and start points. 
2) Condition 
With the radio button, choose the axis operation or the test operation using positioning 
data No. The axis operation is selected in this section. 
Also, select the type of test operation axis-by-axis. 
• Position Operate 
Test operation is performed from the specified positioning data No. to the positioning 
data No. where the operation pattern has been set to "END". 
• Dec step 
If this type is selected when the operation pattern is "LOCUS", test operation is 
performed up to the positioning data where the operation pattern is "CONTINUE" or 
"END". 
• Every Data No. step 
Independently of the operation pattern, operation is performed per data, starting with 
the specified positioning data No., and the axis stands by after operation.