Mitsubishi Electronics AD75P1/P2/P3 ユーザーズマニュアル

ページ / 212
 
 
 
11 - 46                                                                                                                                                       11 - 46 
MELSOFT
11. POSITIONING DEBUGGING 
 
 
 
DISPLAY/SETTING DATA
 
 
Item Description 
Servo status 
External I/O 
Shows the servo status and external I/O signals. 
When the signals are in the following states, the position loop gain 1 test can be made. 
• Servo ON, Servo, Upper limit, Lower limit: ON (z) 
• Alarm, Stop signal: OFF ({) 
Upper stroke limit 
Lower stroke limit 
Shows the upper and lower software limits set to the extended parameters 1 (refer to Section 
8.1.3). 
To perform the position loop gain 1 test, set the upper and lower limits to 18000pls or more in 
terms of pulses. 
Address 
Speed 
Indicates the feed address and feed speed of the axis. 
Make sure that the axis is not operating. 
Error 
Warning 
Shows the error and warning codes when an error and warning occur. 
For the error and warning codes, use the help function to check their causes and corrective 
actions. 
"Close" button 
Click this button to close the Servo diagnosis dialog box. 
Position control 
Set the value used to make the position loop gain 1 test. 
The set value is written to the AD75M by clicking the "Change" button. 
However, no value can be set when auto tuning is executed. 
Ax1 
Ax2 
Ax3 
Choose the axis used to conduct the position loop gain 1 test. 
This 
Shows the position loop gain 1 test results as values and waveform data. 
Last 
Before 
Shows the position loop gain 1 test results of the last time and second last time. 
"Change" button 
Click this button to write to the AD75M the value set to Position control. 
"Forward gain" button 
Click this button to perform the position loop gain 1 test in the forward direction. 
"Reverse gain" button 
Click this button to perform the position loop gain 1 test in the reverse direction. 
"Axis all stop" button 
Used to stop the axes operating in the forward or reverse direction in the position loop gain 1 
test.