Honeywell MS4103 ユーザーズマニュアル

ページ / 268
61
Chart L
12
(83)
13
(90)
14
(96)
15
(103)
16
(110)
17
(117)
18
(124)
19
(131)
20
(138)
21
(144)
22
(152)
23
(159)
24
(165)
25
(172)
12
(83)
11
(76)
 13
(90)
14
(96)
15
(103)
16
(110)
17
(117)
18
(124)
12
(83)
11
(76)
13
(90)
14
(96)
15
(103)
16
(110)
17
(117)
18
(124)
19
(131)
20
(138)
21
(144)
22
(152)
23
(159)
24
(165)
25
(172)
19
(131)
20
(138)
21
(144)
22
(152)
23
(159)
24
(165)
25
(172)
7
(48)
8
(55)
9
(62)
10
(69)
0
(0)
10
(69)
20
(138)
30
(207)
40
(276)
60
(414)
70
(483)
50
(345)
80
(552)
90
(621)
100
(690)
110
(759)
120
(828)
130
(897)
140
(966)
150
(1035)
160
(1104)
2-7
(15-50)
4-1
1
(30-75)
8-12 (55-85)
SPRING RANGE
PSI (kPa)
SIZE 2-1/2 IN. AND 3 IN.
WITH 8 IN. D.A. PNEUMATIC ACTUATOR
(NORMALLY OPEN PORTS B TO AB)
 AIR PRESSURE IN ACTUA
TO
R PSI (kPa)
CLOSEOFF PRESSURE RATINGS PSI (kPa)
CLOSEOFF PRESSURE AT VARIOUS CONTROL AIR PRESSURES FOR VGF FLANGED VALVES 
AND MP953 PNEUMATIC ACTUATORS.
AIR PRESSURE REQUIRED TO OPERATE PRESSURE-BALANCED VGF FLANGED VALVES.
1
2
1
SIZE 2-1/2 INCH
SIZE 3 INCH
M22594
2
2
12
(83)
11
(76)
13
(90)
14
(96)
15
(103)
16
(110)
17
(117)
18
(124)
12
(83)
11
(76)
13
(90)
14
(96)
15
(103)
16
(110)
17
(117)
18
(125)
19
(131)
20
(138)
21
(144)
22
(152)
23
(159)
24
(165)
25
(172)
19
(131)
20
(138)
21
(144)
22
(152)
23
(159)
24
(165)
25
(172)
7
(48)
8
(55)
9
(62)
10
(69)
2-7
(15-50)
4-1
1
(30-75)
SPRING RANGE
PSI (kPa)
SIZE 2-1/2 IN., 3 IN., 4 IN., 5 IN., 6 IN.
WITH 13 IN. D.A. PNEUMATIC ACTUATOR
(NORMALLY OPEN PORTS B TO AB)
 AIR PRESSURE IN ACTUA
TO
R PSI (kPa)
CLOSEOFF PRESSURE RATINGS PSI (kPa)
1
SIZE 2-1/2 INCH
SIZE 3-  AND 4-INCH
M22595
SIZE 5- AND 6-INCH
CLOSEOFF PRESSURE AT VARIOUS CONTROL AIR PRESSURES FOR 
VGF FLANGED VALVES AND MP953 PNEUMATIC ACTUATORS.
AIR PRESSURE REQUIRED TO OPERATE PRESSURE-BALANCED VGF VALVES.
1
2
0
(0)
10
(69)
20
(138)
30
(207)
40
(276)
60
(414)
70
(483)
50
(345)
80
(552)
90
(621)
100
(690)
110
(759)
120
(828)
130
(897)
140
(966)
150
(1035)
160
(1104)
2
2
2
Chart O
SPRING   RANGE
PSI   (kPa)
V5011A — 2-1/2 THROUGH 3 IN. D.A. FLANGED BODIES 
WITH  8 IN. D.A. PNEUMATIC ACTUATOR
(NORMALLY OPEN)
4-11
(30-75)
2-7
(15-50)
8-12
(55-85)
7
(50)
14
(95)
17
(120)
18
 (125)
15
(105)
16
(110)
17
(120)
18
(125)
12
(85)
13
(90)
14
(95)
AIR PRESSURE IN ACTUATOR PSI (kPa)
1
16
(110)
12
(85)
13
(90)
15
(105)
11
(75)
14
 (95)
10
(70)
9
(60)
8
(55)
13
 (90)
12
 (85)
11
(75)
0
(0)
30
(205)
50
(345)
20
(140)
40
(275)
60
(415)
CLOSEOFF  PRESSURE  RATINGS  PSI  (kPa)
10
(70)
USE 4-11 PSI (30-75 kPa) RANGE FOR DETERMINING CLOSEOFF OF VALVES USED WITH 
MP953E ACTUATORS.
1
C3123
15
(105)
DUE TO DIFFERENCES IN VALVE BODY CONSTRUCTION, SCREWED AND FLANGED 
PATTERNS HAVE DIFFERENT CLOSEOFF RATINGS. THIS APPLIES TO 2-1/2 AND 3 IN. 
VALVE SIZES.
2
5
(35)
15
(105)
25
(170)
35
(240)
45
(310)
55
(380)
C
v  = 100
2
C
v  = 63
2
Chart M
M22869
SPRING   RANGE
PSI   (kPa)
SIZE 2-1/2 AND 3 IN. D.A. FLANGED BODIES 
WITH 7 IN. R.A. PNEUMATIC ACTUATOR
(NORMALLY CLOSED)
4-1
1
(30-75
)
8-13 (55-90)
1
 (7)
5
(35)
4
(30)
3
(20)
8
(55)
7
(50)
6
(40)
AIR PRESSURE IN ACTU
AT
OR PSI (kPa)
0
(0)
1
 (7)
2
 (15)
3
 (20)
4
(30)
0
(0)
30
(207)
50
(345)
20
(138)
40
(276)
60
(414)
CLOSEOFF  PRESSURE  RATINGS  PSI  (kPa)
10
(69)
5
(35)
15
(104)
25
(172)
35
(241)
45
(310)
55
(379)
 0
 (0)
2
 (15)
USE 8-13 PSI (55-90 kPa) RANGE FOR DETERMINING CLOSEOFF OF VALVES 
USED WITH MP953F ACTUATORS.
SI
ZE 
2-1/2 IN
CH
SIZE 3 INCH
1
1
Chart R
SPRING RANGE PSI (kPa)
L - LOWER SEAT
U - UPPER SEAT
ACTUATOR AIR PRESSURE IN PSI (kPa)
4-11
(30-75)
11
(75)
12
(85)
13
(90)
14
(95)
15
(105)
16
(110)
17
(115)
18
(125)
4
(30)
3
(20)
2
(15)
1
(5)
0
(0)
L
U
U
L
V5013B-F: 1/2-INCH TO 3-INCH VALVE BODIES WITH
8-INCH D.A. PNEUMATIC ACTUATOR
5
(35)
10
(70)
15
(105)
20
(140)
25
(170)
30
(205)
35
(240)
40
(275)
CLOSEOFF PRESSURE RATING - PSI (kPa)
2-7
(15-50)
7
(50)
8
(55)
9
(60)
10
(70)
11
(75)
12
(85)
13
(90)
14
(95)
2
(15)
1
(5)
0
(0)
L
U
U
L
MIXING
DIVERTING
1
1
USE 4-11 PSI (30-75 kPa) RANGE FOR DETERMINING CLOSEOFF OF VALVES WITH MP953E
ACTUATORS.
C1988-1
8-12
(55-85)
12
(85)
13
(90)
14
(95)
15
(105)
16
(110)
17
(115)
18
(125)
1
(5)
8
(55)
7
(50)
6
(40)
L
U
U
L
5
(35)
4
(30)
3
(20)
2
(15)
45
(310)
55
(380)
65
(450)
50
(345)
60
(415)
70
(485)
Cv = 2.5, 4.0, 6.3
C
v  = 16
C
v  = 25
C
v  = 63
C
v  = 100
C
v  = 40
Cv = 10
Chart S
SPRING RANGE PSI (kPa)
L - LOWER SEAT
U - UPPER SEAT
ACTUATOR AIR PRESSURE IN PSI (kPa)
V5013B, C:
4-INCH, 5-INCH, AND 6-INCH VALVE BODIES WITH
13-INCH D.A. PNEUMATIC ACTUATOR
4-11
(30-75)
11
(75)
12
(85)
13
(90)
14
(95)
15
(105)
16
(110)
17
(115)
18
(125)
4
(30)
3
(20)
2
(15)
1
(5)
0
(0)
L
U
U
L
5
(35)
10
(70)
15
(105)
20
(140)
25
(170)
30
(205)
35
(240)
40
(275)
CLOSEOFF PRESSURE RATING - PSI (kPa)
C
v  = 160
C
v  = 250
C
v  = 360
2-7
(15-50)
7
(50)
8
(55)
14
(95)
2
(15)
1
(5)
L
U
U
L
MIXING
DIVERTING
1
1
USE 4-11 PSI (30-75 kPa) RANGE FOR DETERMINING CLOSEOFF OF VALVES WITH 
MP953E ACTUATORS.
C1986-1
9
(60)
10
(70)
11
(75)
12
(85)
13
(90)
0
(0)
ACTUATOR AIR PRESSURE IN PSI (kPa)
Chart T
SPRING RANGE PSI (kPa)
L - LOWER SEAT
U - UPPER SEAT
4-11
(30-75)
11
(75)
12
(85)
13
(90)
14
(95)
15
(105)
16
(110)
17
(115)
18
(125)
4
(30)
3
(20)
2
(15)
1
(5)
0
(0)
U
L
L
U
V5013B-F: 1/2-INCH TO 3-INCH VALVE BODIES WITH
7-INCH R.A. PNEUMATIC ACTUATOR
5
(35)
10
(70)
15
(105)
20
(140)
25
(170)
30
(205)
35
(240)
40
(275)
CLOSEOFF PRESSURE RATING - PSI (kPa)
3-7
(15-50)
7
(50)
8
(55)
9
(60)
10
(70)
11
(75)
12
(85)
13
(90)
14
(95)
3
(20)
2
(15)
1
(5)
U
L
L
U
MIXING
DIVERTING
USE 8-12 PSI (55-85 kPa) RANGE FOR DETERMINING CLOSEOFF OF VALVES WITH 
MP953F ACTUATORS.
C1987-1
8-12
(55-85)
12
(85)
13
(90)
14
(95)
15
(105)
16
(110)
17
(115)
18
(125)
1
(5)
8
(55)
7
(50)
6
(40)
U
L
L
U
5
(35)
4
(30)
3
(20)
2
(15)
45
(310)
55
(380)
65
(450)
50
(345)
60
(415)
70
(485)
0
(0)
Cv = 2.5, 4.0, 6.
0
C
v  = 10
C
v  = 16
C
v  = 25
C
v  = 40
C
v  = 63
C
v  = 100
ACTUATOR AIR PRESSURE IN PSI (kPa)
1
1
Chart U
12
(85)
11
(75)
 13
(90)
14
(95)
15
(105)
16
(110)
17
(120)
18
(125)
12
(85)
11
(75)
13
(90)
14
(95)
15
(105)
7
(50)
8
(55)
9
(60)
10
(70)
0
(0)
10
(70)
20
(140)
30
(205)
40
(275)
60
(515)
70
(480)
50
(345)
80
(550)
90
(620)
100
(690)
110
(760)
120
(825)
130
(895)
140
(965)
2-7
(15-50)
4-1
1
(30-75)
SPRING RANGE
PSI (kPa)
V5011A — 2-1/2 AND 3 IN. DA FLANGED BODIES
WITH 13 IN. D.A. PNEUMATIC ACTUATOR
(NORMALLY OPEN)
 AIR PRESSURE IN 
ACTUA
T
OR PSI (kPa)
CLOSEOFF PRESSURE RATINGS PSI (kPa)
USE 4-11 PSI (30-75 kPa) RANGE FOR DETERMINING CLOSEOFF OF VALVES USED WITH 
MP953E ACTUATORS.
DUE TO DIFFERENCES IN VALVE BODY CONSTRUCTION, SCREWED AND FLANGED PATTERNS 
HAVE DIFFERENT CLOSEOFF RATINGS. THIS APPLIES TO 2-1/2 AND 3 IN. VALVE SIZES.
1
2
2
2
1
C3118
C
v  = 100
C
v  = 63
Chart P
C3124-2
SPRING   RANGE
PSI   (kPa)
V5011A — 2-1/2 AND 3 IN. D.A. FLANGED BODIES 
WITH  R.A. PNEUMATIC ACTUATOR
(NORMALLY CLOSED)
4-1
1
(30-75)
8-13 (55-90)
1
 (10)
5
(35)
4
(30)
3
(20)
8
(55)
7
(50)
6
(40)
AIR PRESSURE IN ACTUA
TO
R PSI (kPa)
0
(0)
1
 (10)
2
 (15)
3
 (20)
4
(30)
0
(0)
30
(205)
50
(345)
20
(140)
40
(275)
60
(415)
CLOSEOFF  PRESSURE  RATINGS  PSI  (kPa)
10
(70)
DUE TO DIFFERENCES IN VALVE BODY CONSTRUCTION, SCREWED AND 
FLANGED PATTERNS HAVE DIFFERENT CLOSEOFF RATINGS. THIS APPLIES 
TO 2-1/2 AND 3 IN. VALVE SIZES.
5
(35)
15
(105)
25
(170)
35
(240)
45
(310)
55
(380)
 0
 (0)
2
 (15)
USE 8-13 PSI (55-90 kPa) RANGE FOR DETERMINING CLOSEOFF OF VALVES 
USED WITH MP953F ACTUATORS.
C
v  = 63
C
v  = 100
1
1
2
2
2
Chart N
VA
lV
e Selection
Flanged Globe Valves 2½- 3"
With Pneumatic Actuators