Mitsubishi Electronics QD75D ユーザーズマニュアル

ページ / 768
6 - 4
MELSEC-Q
6   SEQUENCE PROGRAM USED FOR POSITIONING CONTROL
(b)  When the circuit uses the "intelligent function device" on the source(s) side
and the destination (D) side of a MOV command, change the command to a
FROM command and a TO command.
MOVP
G826
G1
X15
FROMP
D100
X15
K826
H0
K1
U6\
TOP
D100
K1
H6
K1
X0C
X0C
U0\
Set the 
same device.
0
0
(c)  When the circuit uses the "intelligent function device" for a COMPARISON
command, change the command to a FROM command and a
COMPARISON command.
RST
M0
M0
FROMP
D102
M0
K1521
H0
K1
RST
M0
=
G1521
K0
=
D102
K0
0
0
Data read out
U0\
(d)  When the circuit uses the "intelligent function device" for a WAND command,
change the command to a FROM command and a WAND command.
H8
D0
M2
FROMP
D101
M2
K817
H0
K1
0
0
G817
WANDP
U0\
H8
D0
D101
WANDP
Data read out
REMARK
Refer to QCPU (Q mode) User's Manual (Functions and Programs Basic Part) for
the intelligent function devices.
Refer to QCPU (Q mode) Programming Manual (Common Commands Part) for
detail commands used in those programs shown in this chapter and subsequent.