Mitsubishi Electronics QD75D ユーザーズマニュアル
1 - 20
MELSEC-Q
1 PRODUCT OUTLINE
1.2.3 Outline of stopping
Each control is stopped in the following cases.
(1) When each control is completed normally.
(2) When the drive unit READY signal is turned OFF.
(3) When a PLC CPU error occurs
(4) When the PLC READY signal is turned OFF.
(5) When an error occurs in the QD75.
(6) When control is intentionally stopped (Stop signal from PLC CPU turned ON, stop
signal from an external device, etc.)
The outline for the stopping process in these cases is shown below. (Excluding (1) for
normal stopping.)
Stop process
OPR control
Manual control
Stop cause
Stop
axis
M code
ON signal
after stop
Axis
operation
status
after
stopping
( Md.26 )
Machine
OPR
control
Fast
OPR
control
Major
positioning
control
positioning
control
High-level
positioning
control
positioning
control
JOG/
Inching
operation
Inching
operation
Manual
pulse
generator
operation
pulse
generator
operation
Forced stop
Drive unit
READY
signal OFF
READY
signal OFF
Each
axis
axis
No
change
change
During
error
error
Immediate stop
Deceleration
stop
stop
Fatal stop
(Stop group 1)
(Stop group 1)
Hardware
stroke limit
upper/lower
limit error
occurrence
stroke limit
upper/lower
limit error
occurrence
Each
axis
axis
No
change
change
During
error
error
Deceleration stop/sudden stop
(Select with “ Pr.37 Sudden stop group1
sudden stop selection” )
Deceleration
stop
PLC CPU
error
occurrence
error
occurrence
No
change
change
PLC READY
signal OFF
signal OFF
Turns
OFF
OFF
Emergency
stop
(Stop group 2)
stop
(Stop group 2)
Error in test
mode
mode
All
axes
axes
No
change
change
During
error
error
Deceleration stop/sudden stop
(Select with “ Pr.38 Sudden stop group2
sudden stop selection” )
Deceleration
stop
Axis error
detection
(Error other
than stop
group 1 or 2)
detection
(Error other
than stop
group 1 or 2)
Relatively safe
stop
(Stop group 3) “Stop signal”
stop
(Stop group 3) “Stop signal”
from
peripheral
device
peripheral
device
Each
axis
axis
No
change
change
During
error
error
"Stop signal"
ON from
external
source
ON from
external
source
Intentional stop
(Stop group 3) "Axis stop
(Stop group 3) "Axis stop
signal" ON
from PLC
CPU
from PLC
CPU
Each
axis
axis
No
change
change
When
stopped
(While
waiting)
stopped
(While
waiting)
Deceleration stop/sudden stop
(Select with “
Pr.39 Sudden stop group3
sudden stop selection”)
Deceleration
stop