B101502-1-0311
l
OcatiOn
, c
OnnectiOns
anD
 s
aFety
Built-In Kit Location
Built-In Kits are designed for outdoor use ONLY. 
This Built-In Kit is designed for use with all P3 and T3 Model 
Broilmaster
®
 gas grills and cannot be used with any other 
grill or in any other capacity.
Never  install  or  operate  your  Built-In  Kit  in  any  building, 
garage, or other enclosed area. 
For your safety, the Built-In Kit should not be installed or 
operated under any combustible materials, such as carports, 
covered porches, awnings, or overhangs.
Never install or use your Built-In Kit in or on any recreational 
vehicle or boat.
CAUTION:  THE  INSTALLATION  AND  OPERATION  OF 
THIS  BUILT-IN  KIT  AT  CLEARANCES  LESS  THAN 
SPECIFIED BELOW MAY LEAD TO THE POSSIBILITY OF 
FIRE, PROPERTY DAMAGE, OR PERSONAL INJURY.
A minimum clearance of twenty-four (24”) inches is required 
from all sides of the island to any combustible material.
Examples  of  combustible  materials  are  patio  furniture, 
fences, or the outside of your home.
The area surrounding the built-in kit should be clear to ensure 
proper ventilation. Do not obstruct the flow of combustion 
and ventilation air in any way. The ventilation openings on 
the enclosure must also remain free and clear of debris.
WARNING: DO NOT INSTALL OR OPERATE THIS BUILT-
IN  KIT  WHERE  GASOLINE  OR  OTHER  FLAMMABLE 
MATERIALS  ARE  USED  OR  STORED.  FAILURE  TO 
COMPLY  WITH  THIS  WARNING  COULD  RESULT  IN 
EXPLOSION OR FIRE CAUSING PROPERTY DAMAGE 
OR PERSONAL INJURY.
Connection Requirements
CAUTION:  NEVER  USE  LIQUID  PROPANE  GAS  IN  A 
GRILL DESIGNED FOR NATURAL GAS, OR NATURAL 
GAS  IN  A  GRILL  DESIGNED  FOR  LIQUID  PROPANE 
GAS. QUESTIONS REGARDING DIFFERENT TYPES OF 
GASES SHOULD BE DIRECTED TO YOUR LOCAL GAS 
COMPANY.
Installation must conform to local codes or, in the absence 
of  local  codes,  with  the  National  Fuel  Gas  Code,  ANSI 
Z223.1. In Canada, installation shall be in accordance with 
CAN/CGA-B149.2  Propane  Installation  Code,  or  CAN/
CGA-B149.1  Natural  Gas  Installation  Code,  and  local 
codes where applicable. Consult your local gas company or 
Propane gas dealer for code regulations and recommended 
procedures.
Broilmaster
®
 gas grills and side burners are NOT equipped 
with pressure regulators. Your Nat. gas grill operates at a 
manifold pressure of seven (7”) inches water column.
CAUTION: THE GRILL AND ITS INDIVIDUAL SHUTOFF 
VALVE  MUST  BE  DISCONNECTED  FROM  THE  GAS 
SUPPLY  PIPING  SYSTEM  DURING  ANY  SYSTEM 
PRESSURE TESTING AT TEST PRESSURES IN EXCESS 
OF 1/2 PSIG.
Checking for Gas Leaks
CAUTION: DO NOT USE AN OPEN FLAME TO CHECK 
FOR  LEAKS.  CHECKING  FOR  LEAKS  WITH  AN 
OPEN FLAME MAY LEAD TO A FIRE OR EXPLOSION, 
RESULTING  IN  PROPERTY  DAMAGE  OR  PERSONAL 
INJURY.
Using the following steps, check for gas leaks during initial 
use and each time your Broilmaster
®
  gas grill or side burner 
is connected to gas or is connected to a cylinder that has 
not been used recently
1.  Using dish washing detergent and water, make a soapy 
solution. 
2.  Turn OFF the knob on both the grill and side burner’s 
control panel. 
3.  Turn ON the gas at the supply. A hissing sound indicates 
a leak. Turn OFF the gas and repair all leaks.
4.  If no hissing occurs, apply the soapy solution to all gas 
connections.
5.  Look for bubbles. Bubbles indicate a leak.
6.  If  there  are  bubbles,  turn  OFF  the  gas  and  repair  all 
leaks.
7.  Turn the gas ON and repeat the above procedure until 
all leaks are repaired.